Flammability rating according to UL 94
Insulation resistance
≥ 100 MΩ
≥ 100 MΩ*km (at 20 °C)
Nominal voltage U<sub>N</sub>
Nominal current I<sub>N</sub>
Insertion/withdrawal cycles
Type
free cable end
Socket straight M12
Conductor structure signal line
Wire diameter incl. insulation
1.6 mm ±0.05 mm (Signal line)
Single wire, color
brown, white, blue, black
Thickness, insulation
approx. 0.30 mm (Core insulation)
approx. 0.45 mm (Inner sheath)
approx. 0.70 mm (Outer cable sheath)
Length of twist, overall twist
Max. conductor resistance
Cable capacity
≤ 100 nF/km (Conductor-conductor, asymmetrical/touching)
≤ 150 nF/km (Wire/shield)
≤ 85 nF/km (Conductor-conductor, symmetrical/star quad)
Smallest bending radius, fixed installation
Smallest bending radius, movable installation
Dynamic load capacity (bending)
Max. bending cycles: 1000000, Bending radius: 68 mm, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s²
Halogen-free
in accordance with DIN VDE 0472 part 815
Flame resistance
according to DIN 60332-1-2
according to DIN EN 50266-2-5
Resistance to oil
in accordance with DIN EN 60811-2-1
Other resistance
UV resistant (according to DIN VDE 0276-605)
Ambient temperature (operation)
-15 °C ... 105 °C (Cable, flexible installation)
-40 °C ... 105 °C (cable, fixed installation)
Ambient temperature (operation) (male connector/female connector)
-40 °C ... 105 °C (Plug / socket)