PSR-MC31-2SDO-1DO-24DC-SC Safety relay module
N
0%
1015520

PSR-MC31-2SDO-1DO-24DC-SC Safety relay module

Manufactured by
Brand PHOENIX CONTACT
Safety relay module for safety shut-off mats, switching strips, emergency stop, safety doors, and light grids up to SIL 3, Cat. 4, PL e, 1 or 2-channel operation, automatic or manual start, 2 safe HL outputs, 1 signal output, US = 24 V DC, plug-in screw terminal block
4055626496931
only
available
100+
3
pcs.
(2026-08-29)
Supply from Phoenix Contact’s warehouse
Product recommended retail price (RRP) is
000
24410 0 € pcs.
All prices without tax
All prices with tax
inquiry
only
available
100+
inquiry
0
2026-08-29
pcs.
Properties
Description
Dimensions
Files
Codes
Note on application
Only for industrial use
Typ. starting time with Us
< 200 ms (with U<sub>s</sub> when controlled via A1)
Product type
Safety relays
Rated control circuit supply voltage US
19.2 V DC ... 30 V DC
24 V DC -20 % / +25 % (provide external protection)
Product family
PSRmini
Rated control supply current IS
typ. 54 mA (No load)
Application
Emergency stop
Light grid
Safety door
Safety shut-off mats
Power consumption at US
typ. 1.3 W (No load)
Control
1 and 2 channel
Protection class
II
Overvoltage category
III
Degree of pollution
2
Typical response time
< 175 ms (manual, monitored start)
< 200 ms (automatic start)
Typ. starting time with U&lt;sub&gt;s&lt;/sub&gt;
< 200 ms (with U<sub>s</sub> when controlled via A1)
Response time
< 10 ms (Take the extension of the response time into consideration if you switch several devices in sequence.)
Restart time
< 250 ms (Boot time)
Recovery time
100 ms (Availability time after activating the sensor circuit during manual start)
250 ms (following demand of the safety function)
Start pulse length
min. 250 ms (manual start)
Maximum power dissipation for nominal condition
3.1 W (U<sub>B</sub> = 30 V , I<sub>L1</sub> = I<sub>L2</sub> = 2.4 A)
Nominal operating mode
100% operating factor
Rated insulation voltage
50 V AC
Rated surge voltage/insulation
See data sheet, section “Insulation coordination”.
Designation
A1/A2
Rated control circuit supply voltage U&lt;sub&gt;S&lt;/sub&gt;
19.2 V DC ... 30 V DC
24 V DC -20 % / +25 % (provide external protection)
Rated control supply current I&lt;sub&gt;S&lt;/sub&gt;
typ. 54 mA (No load)
Power consumption at U&lt;sub&gt;S&lt;/sub&gt;
typ. 1.3 W (No load)
Inrush current
< 10 mA (typ. with U<sub>S</sub> at S10/S12, Δt = 500 µs)
< 10 mA (typ. with U<sub>S</sub>, Δt < 100 ms)
< 10 mA (Δt = 500 µs)
< 5 A (Δt = 200 µs at U<sub>s</sub>)
> -5 mA (typ. with U<sub>S</sub> at S22, Δt = 500 µs)
max. 4.8 A (Δt = 10 ms)
Filter time
1 ms (For the logic. At A1 in the event of voltage dips at U<sub>s </sub>)
Deactivate the switch-on pulses for safety applications.
Does not apply for S22
max. 1.5 ms (Test pulse width of low test pulses)
Test pulse rate = 5 x Test pulse width
Protective circuit
Freewheeling circuit for inductive loads
Parallel protection against polarity reversal; Suppressor diode (Provide external fuse protection, see safety notes. Fuse type: 5 AT)
Suppressor diode
Description of the input
IEC 61131-2 type 3
IEC 61131-2 type 3 (S10, S12) PNP (S22)
non-safety-related
NPN
safety-related
safety-related sensor inputs
Number of inputs
1
2
3
Input voltage range &quot;0&quot; signal
0 V DC ... 5 V DC
0 V DC ... 5 V DC (S10, S12)
S22 open
Input voltage range &quot;1&quot; signal
0 V ... 0 V (S22)
11 V DC ... 30 V DC
11 V DC ... 30 V DC (S10, S12)
19.2 V DC ... 30 V DC
Input current range &quot;0&quot; signal
0 mA ... 2 mA
0 mA ... 2 mA (S10, S12)
Concurrence
Max. permissible overall conductor resistance
150 Ω
Current consumption
-4 mA (S22)
< 5 mA (typ. with U<sub>S</sub> at S35)
< 7 mA (typ. with U<sub>S</sub> at S34)
4 mA (S10, S12)
7 mA
Output description
non-safety-related
PNP
PNP, IEC 61131-2 Type 2
Safety-related digital outputs
Number of outputs
1
2
Output voltage
≥ 23 V DC (U<sub>s</sub> - 1 V)
Leakage current
max. 1 mA (in the safe state)
Ohmic load
min. 12 Ω
min. 240 Ω
Max. capacitive load
max. 10 µF (2.4 A load)
max. 4.7 µF (1 A load)
Max. inductive load
max. 1 H
Limitation of the voltage induced on circuit interruption
max. 50 V
Output current
max. 2.4 A
Min. load current
2 mA
Switching frequency
1 Hz (Resistive, inductive, capacitive)
Output voltage when switched off
< 5 V DC (in the safe state)
Test pulses
< 1 ms (Test pulse width of low test pulses)
Length
0
m
Width
0
m
Height
0
m
Weight Net
0
kg
Weight
0
kg
Package
0
kg
Volume
0
ECLASS-13.0
27371819
ECLASS-15.0
27371819
ETIM 10.0
EC001449
UNSPSC 21.0
39122200
GTIN
4055626496931
ECLASS-15.0 ASSET
27250101
Item accessories
0%
CP-MSTB Coding profile
N
1734634 CP-MSTB Coding profile
004 0 €
only
available
100+
inquiry
0
2026-08-29
pcs.
0%
CR-MSTB Coding section
N
1734401 CR-MSTB Coding section
004 0 €
only
available
100+
inquiry
0
2026-08-29
pcs.
0%
CRIMPFOX 6
N
1212034 CRIMPFOX 6
13010 0 €
only
available
100+
inquiry
0
2026-08-29
pcs.
No related items found