Typ. starting time with Us
typ. 100 ms (when controlled via A1-A2)
Rated control circuit supply voltage US
Rated control supply current IS
Application
Ex
Low demand
Safe switch on
Power consumption at US
typ. 2 W (at U<sub>S</sub>/U<sub>D</sub>; On state)
Diagnostic supply voltage UD
Input current at UD
25 mA (at U<sub>D</sub> = 30 V)
35 mA (at U<sub>D</sub> = 24 V)
45 mA (at U<sub>D</sub> = 19 V)
Power consumption at UD
typ. 0.9 W (at U<sub>D</sub>; Off state)
Typ. starting time with U<sub>s</sub>
typ. 100 ms (when controlled via A1-A2)
Typical release time
typ. 30 ms (when controlled via A1-A2)
Recovery time
1 s (when controlled via A1-A2)
3 s (Availability time for diagnostics after U<sub>D</sub> is applied)
Maximum power dissipation for nominal condition
3.8 W (ati U<sub>B</sub> = 26.4 V DC, U<sub>BD</sub> = 26.4 V DC, I<sub>L</sub> = 3 A)
Rated surge voltage/insulation
Safe isolation, 6 kV reinforced insulation from (A1/A2, 24V/0V, 21/22, and TP1/TP2/TP3) to the enabling current path (L, L', LO, LO', NI, NI', N,N')
Rated control circuit supply voltage U<sub>S</sub>
Rated control supply current I<sub>S</sub>
Power consumption at U<sub>S</sub>
typ. 2 W (at U<sub>S</sub>/U<sub>D</sub>; On state)
Inrush current
≤ 800 mA (Δt 100 ms)
max. 100 mA
max. 5 A (Δt 1 s)
min. 50 mA
typ. 200 mA
Filter time
≥ 100 ms (at A1-A2; low test pulse rate)
≥ 800 ms (at A1-A2; high test pulse rate)
2 ms (at A1-A2 in the event of voltage dips at U<sub>s</sub>)
max. 17 ms (at A1-A2; high test pulse width)
max. 2 ms (at A1-A2; low test pulse width)
Protective circuit
Reverse polarity protection
Surge protection; 33 V suppressor diode
Surge protection; 36 V suppressor diode
Diagnostic supply voltage U<sub>D</sub>
Input current at U
25 mA (at U<sub>D</sub> = 30 V)
35 mA (at U<sub>D</sub> = 24 V)
45 mA (at U<sub>D</sub> = 19 V)
Inrush current at U<sub>D</sub>
Power consumption at U<sub>D</sub>
typ. 0.9 W (at U<sub>D</sub>; Off state)
Current consumption
typ. 20 mA (Input TP1)
typ. 20 mA (Input TP2)
typ. 30 mA (Input TP3)
Output description
non-safety-related N/C contact
safety-related N/O contacts
Number of outputs
1 (undelayed)
1 (without delay, floating)
Contact switching type
1 enabling current path
1 signaling current path
Contact material
AgNi, gold-flashed, Ag alloy
Switching voltage
max. 125 V DC
max. 250 V AC
min. 16 V AC/DC
Limiting continuous current
3 A (Observe derating, load type, and on-load voltage)
Sq. Total current
9 A<sup>2</sup> (observe derating)
Mechanical service life
approx. 5x 10<sup>7</sup> cycles