Note
The nominal current does not apply for fuse versions. In this case, the current is determined by the fuse.
Internal cylindrical gage
Conductor cross-section rigid
Cross section AWG
24 ... 12 (converted acc. to IEC)
Conductor cross-section flexible
Conductor cross-section, flexible [AWG]
24 ... 14 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
Flexible conductor cross-section (ferrule with plastic sleeve)
Conductor cross-section flexible (2 conductors with the same cross-section, with TWIN ferrule and pl
Flammability rating according to UL 94
Static insulating material application in cold
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
Relative insulation material temperature index (Elec., UL 746 B)
Fire protection for rail vehicles (DIN EN 45545-2) R22
Fire protection for rail vehicles (DIN EN 45545-2) R23
Fire protection for rail vehicles (DIN EN 45545-2) R24
Fire protection for rail vehicles (DIN EN 45545-2) R26
Type of plug
Pin connector pattern type E
Specification
DIN EN 50155 (VDE 0115-200):2022-06
Spectrum
Long life test category 2, bogie-mounted
Frequency
f<sub>1</sub> = 5 Hz to f<sub>2</sub> = 250 Hz
Test directions
X-, Y- and Z-axis
X-, Y- and Z-axis (pos. and neg.)
Number of shocks per direction
Ambient temperature (operation)
-5 °C ... 40 °C (according to IEC 60884-1, average value over a period of 24 hours not above +35°C)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)