Note
Depending on the application case and mechanical load, other arrangements of the mounting accessory can also be chosen.
For versions with 6 or 7 connections, it is enough to place one DIN rail adapter centrally per block and place flange elements after every other block.
When using the DIN rail adapter PTFIX-NS35, an aligned block must not protrude by more than a half.
Product type
Distributor terminal block
Maximum power dissipation for nominal condition
Number of connections per level
Internal cylindrical gage
Connection in acc. with standard
Conductor cross-section rigid
0.5 mm² ... 16 mm²
1 mm² ... 16 mm²
Cross section AWG
20 ... 6 (converted acc. to IEC)
Conductor cross-section flexible
Conductor cross-section, flexible [AWG]
20 ... 6 (converted acc. to IEC)
Maximum load current
76 A (with a 16 mm² conductor cross-section, rigid)
Maximum total current
90 A (The load current of all connected conductors must not exceed the maximum total current.)
Conductor cross-section flexible (ferrule without plastic sleeve)
Flexible conductor cross-section (ferrule with plastic sleeve)
Flammability rating according to UL 94
Insulating material group
Static insulating material application in cold
Relative insulation material temperature index (Elec., UL 746 B)
Specification
DIN EN 50155 (VDE 0115-200):2018-05
Spectrum
Long life test category 2, bogie-mounted
Frequency
f<sub>1</sub> = 5 Hz to f<sub>2</sub> = 250 Hz
Test directions
X-, Y- and Z-axis
X-, Y- and Z-axis (pos. and neg.)
Number of shocks per direction
Ambient temperature (operation)
-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)