Flammability rating according to UL 94
Material of grip body
TPU, hardly inflammable, self-extinguishing
Nominal voltage U<sub>N</sub>
Nominal current I<sub>N</sub>
Type
free cable end
Socket straight M8
UL AWM Style
20549 / 10493 (80°C/300 V)
Cable type
PUR halogen-free black [PUR]
Conductor structure signal line
Wire diameter incl. insulation
Single wire, color
brown, white, blue, black
Max. conductor resistance
Minimum bending radius, fixed installation
Minimum bending radius, flexible installation
Smallest bending radius, fixed installation
Smallest bending radius, movable installation
Dynamic load capacity (bending)
Flexible cable conduit capable
Halogen-free
in accordance with DIN EN 50267-2-1
in accordance with DIN VDE 0472 part 815
Flame resistance
according to UL 758/1581 (horizontal)
in accordance with UL 758/1581 FT2
Resistance to oil
in accordance with DIN EN 60811-2-1
Other resistance
abrasion-resistant
Highly resistant to acids, alkaline solutions and solvents
hydrolysis and microbe resistant
Low adhesion
partly UV-resistant (in accordance with DIN EN ISO 4892-2-A)