IOA MCR-EX-RTD-I Temperature measuring transducer
N
0%
1085764

IOA MCR-EX-RTD-I Temperature measuring transducer

Manufactured by
Brand PHOENIX CONTACT
Ex i temperature transducer for VIP I/O marshalling base elements: converts signals from resistance temperature detectors installed in the Ex area and transmits a 0/4 mA ... 20 mA signal to a load (active or passive) in the safe area. Freely configurable.
4055626875606
only
available
100+
99999
pcs.
(2026-08-24)
Supply from Phoenix Contact’s warehouse
Product recommended retail price (RRP) is
000
44180 0 € pcs.
All prices without tax
All prices with tax
inquiry
only
available
100+
inquiry
0
2026-08-24
pcs.
Properties
Description
Dimensions
Files
Codes
Max. internal capacitance Ci
44 nF
Product type
Temperature transmitter
Max. output voltage Uo
6 V
Product family
VIP I/O-Marshalling
Application
Temperature
Max. output current Io
13 mA (Potentiometer)
13 mA (RTD in 3-conductor technology)
16.6 mA (2x RTD in 2-conductor technology)
16.6 mA (RTD in 4-conductor technology)
7.1 mA (RTD in 2-conductor technology)
Max. output power Po
11 mW (RTD in 2-conductor technology)
20 mW (Potentiometer)
20 mW (RTD in 3-conductor technology)
25 mW (2x RTD in 2-conductor technology)
25 mW (RTD in 4-conductor technology)
No. of channels
1
Configuration
Software
Safety-related maximum voltage Um
110 V DC (≤ 2000 m)
121 V AC (≤ 2000 m)
121 V AC/DC (> 2000 m ... 3000 m)
30 V DC (Zone 2: CHn+, CHn-)
33 V AC/DC (> 4000 m ... 5000 m)
60 V AC/DC (> 3000 m ... 4000 m)
Electrical isolation
3-way isolation
IIA (simple circuit): Max. external inductivity Lo / Max. external capacitance Co
850 mH / 1000 µF
Electrical isolation between input and output
yes
IIB/IIIC (simple circuit): Max. external inductivity Lo / Max. external capacitance Co
460 mH / 1000 µF
IIC (simple circuit): Max. external inductivity Lo / Max. external capacitance Co
100 mH / 40 µF
Step response (0–99%)
≤ 1.7 s (with filter factor = 1)
IIB/IIA/IIIC (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co
100 mH / 950 nF, 50 mH / 950 nF, 5 mH / 950 nF, 1 mH / 950 nF
Maximum temperature coefficient
0.01 %/K
IIC (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co
100 mH / 555 nF, 50 mH / 555 nF, 5 mH / 555 nF, 1 mH / 555 nF, 10 µH / 555 nF
Transmission error, typical
0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)
Overvoltage category
II (≤ 5000 m)
Pollution degree
2 (≤ 5000 m)
Standards/regulations
EN 61000-4-3
EN 61000-4-4
EN 61000-4-6
EN 61000-6-4
GB/T 3836.1
GB/T 3836.3
GB/T 3836.4
IEC/EN 60079-11
IEC/EN 60079-7
IEC/EN 61010-1
Rated insulation voltage
150 V<sub>rms</sub>
150 V<sub>rms</sub> (Input/output, power supply)
150 V<sub>rms</sub> (Input/output/power supply)
162 V<sub>rms</sub> (Input/output/power supply)
200 V<sub>rms</sub>
212 V<sub>P</sub>
212 V<sub>P</sub> (Input/output, power supply)
230 V<sub>P</sub> (Input/output/power supply)
251 V<sub>rms</sub>
355 V<sub>P</sub>
60 V<sub>rms</sub> (Input/output, power supply)
60 V<sub>rms</sub> (Input/output/power supply)
84 V<sub>P</sub> (Input/output, power supply)
84 V<sub>P</sub> (Input/output/power supply)
Test voltage
2.3 kV AC (50 Hz, 60 s)
Insulation
Double/reinforced insulation
Nominal supply voltage
24 V DC
Supply voltage range
19.2 V DC ... 30 V DC
Max. current consumption
< 40 mA (24 V DC)
Power dissipation
≤ 0.7 W (Active output)
≤ 1 W (Passive output)
Power consumption
≤ 0.73 W (Passive output)
≤ 1 W (Active output)
Number of inputs
1
Input signal
Resistor
Temperature
Description of the input
intrinsically safe
Sensor types (RTD) that can be used
Pt, Ni, Cu, Si sensors: 2, 3, 4-conductor
Temperature measuring range
-200 °C ... 850 °C (Range depending on the sensor type)
≥ 100 K (R0: 10 Ω ... 100 Ω)
≥ 20 K (R0: 100 Ω ... 10000 Ω)
Linear resistance measuring range
0 Ω ... 50 kΩ
Potentiometer resistance range
0 Ω ... 50 kΩ
Max. permissible overall conductor resistance
25 Ω (Per cable)
Sensor input current
10 µA ... 210 µA (Up to 2x 210 µA with 3-conductor technology)
Number of outputs
1
Configurable/programmable
Yes
Current output signal
0 mA ... 20 mA
4 mA ... 20 mA (active)
4 mA ... 20 mA (Passive, external source voltage 19.2 V ... 26.4 V)
Max. current output signal
21 mA
Load/output load current output
≤ 600 Ω
Output ripple
< 14 mV<sub>rms</sub>
< 20 mV<sub>PP</sub>
Output ripple (current)
< 10 µA<sub>rms</sub>
< 15 µA<sub>PP</sub>
Behavior in the event of a sensor error
As per NE 43 or can be freely defined
Connection method
Micro USB type B
Plug-in connection
Number of connections
1
Length
0
m
Width
0
m
Height
0
m
Weight Net
0
kg
Weight
0
kg
Package
0
kg
Volume
0
ECLASS-13.0
27210129
ECLASS-15.0
27210129
ETIM 10.0
EC002919
UNSPSC 21.0
41112105
GTIN
4055626875606
Item accessories
0%
VIP/S/D25M/BASE 1-8/L/C/EX Base module
N
2906595 VIP/S/D25M/BASE 1-8/L/C/EX Base module
22410 0 €
only
available
100+
inquiry
0
pcs.
0%
BASE-MSTB/D37M/16CH/EX Base module
N
1065476 BASE-MSTB/D37M/16CH/EX Base module
41410 0 €
only
available
100+
inquiry
0
2026-11-14
pcs.
0%
IOA MCR-CJC-PT100 Plug
N
1085776 IOA MCR-CJC-PT100 Plug
5270 0 €
only
available
100+
inquiry
0
2026-08-29
pcs.
0%
IFS-USB-PROG-ADAPTER Programming adapter
N
2811271 IFS-USB-PROG-ADAPTER Programming adapter
15590 0 €
only
available
100+
inquiry
0
pcs.
0%
UC-TM  6 Marker for terminal blocks
N
0818085 UC-TM 6 Marker for terminal blocks
678 0 €
only
available
100+
inquiry
0
2026-08-29
pcs.
0%
UC-TM  6 BU Marker for terminal blocks
N
0818344 UC-TM 6 BU Marker for terminal blocks
678 0 €
only
available
100+
inquiry
0
2026-08-29
pcs.
0%
ZB 5,08:UNBEDRUCKT Zack marker strip
N
0809793 ZB 5,08:UNBEDRUCKT Zack marker strip
069 0 €
only
available
100+
inquiry
0
2026-08-29
pcs.
No related items found