Connection method
Card edge connector
Push-in connection
Transmission speed
See system in which you use the Smart Element.
Start time until ready to operate
Required configuration data
Switching current
max. 110 mA DC (250 V DC, L/R ≤ 50 ms)
max. 125 mA (at 220 V DC)
max. 220 mA DC (125 V DC, L/R ≤ 50 ms)
max. 250 mA (at 110 V DC)
max. 3 A (up to 30 V DC, N/C contact, general use)
max. 580 mA (at 48 V DC)
max. 6 A (up to 250 V AC, cos phi = 0.75 ... 0.8)
max. 6 A (up to 30 V DC, N/O contact, general use)
Switching power
For further DC values, see DC load limit curve.
max. 1500 VA (AC applications up to 55°C, observe derating above that)
max. 180 W (up to 30 V DC, N/O contact, general use)
max. 28 W (above 30 V DC)
max. 90 W (up to 30 V DC, N/C contact, general use)
Switching capacity in accordance with IEC 60947-5-1
0.1 A (220 V (DC13), L/R = 44 ms)
0.2 A (110 V (DC13), L/R = 44 ms)
2 A (24 V (DC13), L/R = 100 ms)
3 A (120 V (AC15))
3 A (230 V (AC15))
3 A (24 V (AC15))
Switching capacity in accordance with UL/CSA 61010-2-201
1 A (DC, R300, up to max. 60°C)
5 A (AC, B300, up to max. 55°C)
Mechanical service life
20x 10<sup>6</sup> cycles
Mounting position
See the system in which the Smart Element is used.
Overvoltage category
III (EN 61010-2-201/IEC 61010-2-201)
Pollution degree
2 (IEC 60664-1, EN 60664-1)
Maximum power dissipation for nominal condition
Supply voltage
24 V DC (using card edge connectors)
using card edge connectors
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw
typ. 36 mA (18 mA per relay, all contacts floating)
Protective circuit
Reverse polarity protection; parallel diode
Surge protection; See the system in which the Smart Element is used.
Protection
See the system in which the Smart Element is used.
Test voltage: Communications supply / 24 V supply (I/O)
Test voltage: Communications supply / functional ground
Test voltage: 24 V supply (I/O) / functional ground
Test voltage: Supply logic / relay contact
Test voltage: 24 V supply (devices) / relay contact
Test voltage: Relay contact / functional ground
Note on the connection method
When selecting the cables, observe the permissible operating temperature in accordance with IEC or UL.
Conductor cross-section, rigid
Conductor cross-section, flexible
Conductor cross-section AWG
Conductor cross-section, flexible, with ferrule, with plastic sleeve
Conductor cross-section, flexible, with ferrule, without plastic sleeve
Ambient temperature (operation)