Your Language:
English (en)
en
English
lt
Lietuviškai
Debug
Administrator
Testing
did you mean:
Show
more results
in separate page
0
items
0
00
Your basket is empty
Total price for
0
items
0
00
All prices
without tax
All prices
with tax
Order
Proceed to basket details
Production catalog
Automation and control
Controllers (PLC)
I/O Modules
HMI and Visualization
Industrial Computers and Communication Equipment
Industrial Computers
Network Equipment
IoT Solutions
Drives and Motion Control
Drives
Frequency Converters / Inverters
Pneumatic Components
Pneumatic Actuators
Pneumatic Valves
Air Preparation
Pneumatic Fittings
Control valves
Sensors and Process Measurement
Proximity Sensors
Optical and Specialized Sensors
Process Measurement
Signal Converters and Transmitters
Accessories for sensors
Encoders
Electrical Engineering and Control Equipment
Switching and Control Equipment
Protection Devices
Control Elements
Power Supplies and Energy
Power Supplies
Energy Conversion
UPS Systems
Energy Distribution
Portable power stations
Connectivity and Cabling
Connectors
Terminal Blocks
Cables
Cable protection
Distribution Panels and Enclosures
Enclosures
Distribution Systems
IT Infrastructure
Enclosure Climate Control
Cooling
Heating
Climate Control
Equipment Safety
Safety Components
Safety Sensors
Emergency Stop Devices
Audible and Visual Signaling
Visual Signaling
Audible Signaling
Industrial Marking
Marking Materials
Printing Equipment
Cable ties
Machine Vision
Industrial Cameras
Vision Sensors
Tools
Special offers
Sale
New products
Brands
Contacts
Delivery information
Information
About us
FAQ
Payment
Delivery methods and conditions
Privacy policy
Contacts
Cookie policy
Our clients
Home
Catalog
Sensors and Process Measurement
Signal Converters and Transmitters
Temperature Transmitters
FA MCR-EX-HT-TS-I-OLP Head-mounted transducer
N
0
%
1105681
FA MCR-EX-HT-TS-I-OLP Head-mounted transducer
Manufactured by
Brand
PHOENIX CONTACT
Ex i-Output loop-powered head transmitter for transmitting up to 2 sensor signals from RTD and TC sensors as well as from resistance and voltage sensors via 4 mA ... 20 mA. HART, Standard configuration, Safety Integrity Level (SIL, IEC 61508): 2, Systematic Capability: 3, Screw connection
4055626988863
only
available
100+
99999
pcs.
(2026-09-15)
Supply from Phoenix Contact’s warehouse
Product
recommended retail price (RRP)
is
0
00
€
516
30
€
0 €
pcs.
All prices
without tax
All prices
with tax
inquiry
only
available
100+
inquiry
0
2026-09-15
pcs.
Add to basket
Properties
Description
Dimensions
Files
Codes
Product type
Temperature transmitter
Product family
Field Analog
No. of channels
2
Configuration
HART
Software
Overvoltage category
II
Pollution degree
2
Electrical isolation between input and output
yes
Step response (0–99%)
0.8 s (TC)
Test voltage
2 kV AC (50 Hz, 60 s)
Supply voltage range
11 V DC ... 30 V DC (Ex)
11 V DC ... 32 V DC (SIL active)
11 V DC ... 42 V DC (Standard)
loop-powered, no external supply necessary
Number of inputs
2
Input voltage range
-20 mV ... 100 mV (Minimum measuring span: 5 mV)
Sensor types (RTD) that can be used
Pt, Ni, Cu sensors: 2, 3, 4-wire
Sensor types that can be used (TC)
A, B, C, D, E, J, K, L, N, R, S, T, U
Temperature measuring range
-200 °C ... 850 °C (Pt 100)
-250 °C ... 2500 °C (Range depending on the sensor type)
> 10 K (RTD)
> 50 K (TC)
Linear resistance measuring range
10 Ω ... 2000 Ω (Minimum measuring span: 10 Ω)
Current output signal
20 mA ... 4 mA (HART)
4 mA ... 20 mA (HART)
Max. current output signal
23 mA
Load
(U<sub>B</sub> – 11 V) / 0.023 A
HART coding
FSK ± 0.5 mA
HART version
7
Transmission speed
1200 Baud
Mains frequency filter
50/60 Hz
Communication resistance
≥ 250 Ω
Switch-on delay
10 s (HART)
28 s (Measured value)
Connection method
Screw connection
Stripping length
8 mm
Screw thread
M3
Conductor cross-section rigid
0.2 mm² ... 2.5 mm²
Conductor cross-section flexible
0.2 mm² ... 2.5 mm²
Conductor cross-section AWG
24 ... 14
Tightening torque
0.35 Nm
Ex installation (EPL)
Div. 1
Gb
Ex i circuits (EPL)
Div. 1
Ga
Protocols supported
HART
Degree of protection
IP00 (upon installation in field housing IP66/67, NEMA 4X)
Ambient temperature (operation)
-40 °C ... 70 °C (SIL active)
-40 °C ... 85 °C
Ambient temperature (storage/transport)
-50 °C ... 100 °C
Altitude
≤ 4000 m (Above sea level)
Climatic class
C1
Permissible humidity (operation)
5 % ... 95 % (condensation permitted)
Certificate
CE-compliant
DNV GL TAA00002GX
EPS 17 ATEX 1 130 X
IECEx EPS 17.0076X
Identification
2
3
Ex ia IIC T6...T4 Ga
Ex ia IIC T6...T4 Gb
Exia / Class I / Group ABCD T6/T5/T4
IS / Class I / Div. 1, 2 / Group ABCD
NI / Class I / Div. 1, 2 / Group ABCD T6/T5/T4
UL 61010 Recognized
II 1G Ex ia IIC T6...T4 Ga
II 2G Ex ia IIC T6...T4 Gb
Temperature
D
Humidity
B
Vibration
B
EMC
B
Enclosure
C
Mounting type
DIN rail mounting
Installation
Assembly note
Installation in connection head according to DIN 43729 form B
Length
0
m
Width
0
m
Height
0
m
Weight Net
0
kg
Weight
0
kg
Package
0
kg
Volume
0
m³
No files found
ECLASS-13.0
27210129
ECLASS-15.0
27210129
ETIM 10.0
EC002919
UNSPSC 21.0
41112100
GTIN
4055626988863
Item accessories
0
%
N
2309000
MCR-PAC-T-USB Programming adapter
220
70
€
0 €
only
available
100+
inquiry
0
2026-08-29
pcs.
0
%
N
1003824
GW HART USB MODEM Cable adapter
894
40
€
0 €
only
available
100+
inquiry
0
2026-08-29
pcs.
0
%
N
2864671
MCR-DIN-RAIL-ADAPTER HT DIN rail adapter
34
00
€
0 €
only
available
100+
inquiry
0
pcs.
No related items found