Material (Cable gland seal)
Flammability rating according to UL 94
V0 (Housing, a vertically clamped sample is extinguished within 10 seconds, no flaming droplets of molten plastic, smoldering for a maximum of 60 seconds)
V2 (Cable gland; a vertically tensioned sample is extinguished within 30 seconds; flaming droplets are permitted)
Mounting type
Mast mounting
Panel mounting
Basic functions
Store-and-forward switch, complies with IEEE 802.3
Connection method
Push-in spring connection
RJ45 jack
Note on the connection method
Auto negotiation and autocrossing
No. of channels
1 (Push-in Technology)
1 (RJ45 port)
2 (RJ45 ports)
4 (RJ45 PoE ports)
Maximum output power
155 W (If switching output is active, >55°C derating)
165 W (>55°C derating, see data sheet)
30 W (POE4)
90 W (per port POE1...3, >50°C derating, see data sheet)
Single conductor/terminal point, rigid
0.2 mm² ... 1.5 mm²
1 mm² ... 6 mm²
Single-wire/terminal point, flexible
0.2 mm² ... 1.5 mm²
0.2 mm² ... 6 mm²
Conductor cross-section, flexible, with ferrule, with plastic sleeve
0.2 mm² ... 4 mm²
0.25 mm² ... 0.75 mm² (Stripping length 8 mm)
Conductor cross-section, flexible, with ferrule, without plastic sleeve
0.2 mm² ... 4 mm²
0.25 mm² ... 1.5 mm² (Stripping length 8 mm)
Max. AWG conductor cross-section, flexible
Min. AWG conductor cross-section, flexible
Load/output load current output
Output nominal voltage
24 V DC ±10 % (Supply for devices within the Smart Ethernet Box)
MTTF
224 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
441 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
92 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
Protection class
I (Protective grounding of all conductive housing parts)
Overvoltage category
II (Without protection modules)
III (With protection modules plugged in)
Diagnostic functions
ACD (Address Conflict Detection)
LLDP (Link Layer Discovery Protocol)
N:1-Portmirroring
RMON History
SNMP traps
Filter functions
Port prioritization
VLAN (up to 32 VLANs)
IP parameterization
BootP
DHCP client
Static IP address
Management
Command Line Interface (Telnet, SSH)
SNMPv2/v3
Web-based management (HTTP/HTTPS)
Redundancy
FRD (Fast Ring Detection)
Large Tree Support
RSTP (Rapid Spanning Tree Protocol in accordance with IEEE 802.1D-2004)
Time synchronization
SNTP (Simple Network Time Protocol)
Maximum power dissipation for nominal condition
min. 7 W (at 230 V AC, standby mode)
Rated insulation voltage
3 kV AC (Input / output, IEC/EN 60950-1)
Supply voltage range
100 V AC ... 240 V AC -15 % ... +10 % (Single-phase)
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve
Conductor cross-section, flexible [AWG]
Degree of protection
IP65 (in accordance with DIN EN 60529: Complete touch protection, dust cannot enter, spray water from any direction)
Impact strength
IK10 (in accordance with IEC 62262: Impact energy of 20 J, corresponds to 5 kg from a height of 40 cm)
Ambient temperature (operation)
-40 °C ... 70 °C (>50°C derating)