Assembly note
The housing can be opened a maximum of 10 times.
Tightening torque
0.4 Nm ... 0.5 Nm
1.2 Nm ... 1.4 Nm
Note on application
Attach the adhesive pads: Make sure that the surface of the housing is clean, dry, and free of grease. Temperature range: +18°C ... +30°C / Closing pressure force: 60 N / Closing pressure time: 3 s
General
Please observe the application note in the download area.
Housing type
Field housing
Universal housings
Number (Connection openings)
Ventilation openings present
Color (Corner inlay)
turquoise green (RAL 5018)
Flammability rating according to UL 94
CTI according to IEC 60112
Ambient temperature
20 °C
30 °C
40 °C
50 °C
60 °C
Power dissipation
11 W
4.4 W
6 W
7.7 W
9.4 W
Specification
IEC 60068-2-27:2008-02
IEC 60068-2-31:2008-05
IEC 60068-2-6:2007-12
IEC 60529:1989-11 + AMD 1:1999-11 + AMD 2:2013-08
IEC 60695-10-2:2014-02
IEC 60695-2-11:2014-02
VW PV 3.10.7:2005-02
Amplitude
0.15 mm (10 Hz ... 58.1 Hz)
Acceleration
15g
2g (58.1 Hz ... 150 Hz)
Test directions
X-, Y- and Z-axis
X-, Y- and Z-axis (pos. and neg.)
Number of shocks per direction
Result, degree of protection, IP code
Ambient temperature (operation)
-40 °C ... 105 °C (depending on power dissipation)
Ambient temperature (storage/transport)
Ambient temperature (assembly)
Relative humidity (storage/transport)