Rated surge voltage (III/3)
Rated surge voltage (III/2)
Rated surge voltage (II/2)
Note on change in voltage
With a cable cross-section of AWG 18 or 0.75 mm², the rated insulation voltage is reduced to 63 V with a rated surge voltage of 1.5 kV and a pollution degree of 1 or 2, depending on the insulation thickness of the cable used.
Conductor/PCB connection direction
Conductor cross-section flexible
0.14 mm² ... 0.75 mm² (Maximum external diameter of the insulation 1.9 mm)
Conductor cross-section AWG
26 ... 18 (Maximum external diameter of the insulation 1.9 mm)
Metal surface contact area (top layer)
Insulating material group
CTI according to IEC 60112
Flammability rating according to UL 94
Glow wire flammability index GWFI according to EN 60695-2-12
Glow wire ignition temperature GWIT according to EN 60695-2-13
Temperature for the ball pressure test according to EN 60695-10-2
Note on the contact
The information on the basic material and the finish properties of the crimp contacts is to be found in the E-Shop in the technical data for the respective crimp contact.
These connectors conform to DIN EN 61984, connectors without switching power (COC). When used for their intended purpose, they must not be plugged in or disconnected live or under load.
Note on application
All laboratory tests are performed in combination with the crimp contacts specified as accessories.
The corresponding crimp contacts are to be found in the "Accessories" tab.
The crimp contacts may only be processed with approved crimping tools.
The current depends on the crimp contact and conductor cross-section used.
Conductor cross-section/conductor type/tractive force setpoint/actual value
0.14 mm² / flexible / > 18 N
Specification
IEC 60068-2-70:1995-12
IEC 60512-1-1:2002-02
IEC 60512-1-2:2002-02
IEC 60512-13-2:2006-02
IEC 60512-13-5:2006-02
IEC 60512-5-1:2002-02
IEC 60512-9-1:2010-03
IEC 60664-1:2007-04
Insertion strength per pos. approx.
Withdraw strength per pos. approx.
Impulse withstand voltage at sea level
Insertion/withdrawal cycles