Rated control circuit supply voltage US
Input voltage range in reference to UN
Application
Emergency stop
Light grid
Safety door
Typical input current at UN
Mechanical service life
approx. 10<sup>7</sup> cycles
Relay type
Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Typical response time
150 ms (Monitored/manual and auto-start)
Typical release time
100 ms (delayed contacts)
20 ms (Undelayed contacts)
Delay time range
0.1 s ... 30 s ±30 % (adjustable)
Recovery time
1 s (Electric torque)
330 ms (Restart)
Maximum power dissipation for nominal condition
Rated surge voltage/insulation
Rated control circuit supply voltage U<sub>S</sub>
Nominal input voltage U<sub>N</sub>
Input voltage range in reference to U<sub>N</sub>
Typical input current at U<sub>N</sub>
Voltage at input/start and feedback circuit
Typical release time range
Protective circuit
Suppressor diode, 33 V DC
Max. permissible overall conductor resistance
500 Ω (Input and reset circuit at U<sub>N</sub>)
Operating voltage display
Status display
LED (green)
LED K1/K2 and K3(t)/K4(t), green
Maximum switching voltage
Minimum switching voltage
Limiting continuous current
Sq. Total current
120 A<sup>2</sup> (see to derating)
49 A<sup>2</sup>
Interrupting rating (ohmic load) max.
144 W (24 V DC, τ = 0 ms)
1500 VA (250 V AC, τ = 0 ms)
288 W (48 V DC, τ = 0 ms)
88 W (220 V DC, τ = 0 ms)
90 W (110 V DC, τ = 0 ms)
Maximum interrupting rating (inductive load)
23 W (220 V DC, τ = 40 ms)
25 W (110 V DC, τ = 40 ms)
33 W (48 V DC, τ = 40 ms)
42 W (24 V DC, τ = 40 ms)
Switching capacity (360/h cycles)
Switching capacity (3600/h cycles)
3 A (230 V (AC15))
3 A (24 V (DC13))
Output fuse
10 A gL/gG NEOZED (N/O contact)
Switching voltage
max. 250 V AC/DC
min. 15 V AC/DC