Product family
Modular emergency stop switches
Application
Safe shutdown + assembly monitoring
Short-circuit current
1000 A (conditional short-circuit current I<sub>q</sub>)
Contact switching type
1 force-guided N/C contact + 1 N/O contact
Positive opening action
in accordance with EN 60947-5-1, Annex K
Voltage
max. (see load limit current)
min. 5 V
Current
max. (see load limit current)
min. 1 mA
Electrical service life
10<sup>6</sup> switching cycles
Rated insulation voltage Ui
Rated operating voltage Ue
125 V
24 V
240 V
250 V
60 V
Rated operating current Ie (AC-15, 230 V)
Switching capacity
1.1x I<sub>e</sub>
10x I<sub>e</sub>
Thermal continuous current Ith
Rated operating current Ie
Note regarding the connection technology
2 conductors possible per terminal point, with one conductor on each side of the screw
Conductor cross-section rigid
Conductor cross-section flexible
Flexible conductor cross-section with ferrule
Conductor cross-section AWG
20 ... 14 (rigid and flexible conductors without ferrules)
23 ... 14 (flexible conductors with ferrules)
Color (Upper housing part)
Color (Lower housing part)
Flammability rating according to UL 94
Ambient temperature (operation)
-30 °C ... 85 °C (in conjunction with lighting module max. 65°C)
Ambient temperature (storage/transport)
Maximum altitude
max. 2000 m (Above sea level)
Shock
15g / 11 ms, in accordance with IEC 60068-2-27
Vibration (operation)
10 Hz ... 500 Hz, 0.35 mm amplitude, 5g, in accordance with IEC 60068-2-6