Nominal input voltage range
Input current
3x 46 A (400 V AC)
3x 54 A (340 V AC)
Nominal power consumption
Inrush current limitation
Total distortion (THDi)
< 5 % (50% ... 100% output load)
Supply system configuration
Star network (TN, TT, IT (PE))
Efficiency
> 95 % (P<sub>Out</sub> >50%)
Output current residual ripple
Power dissipation standby
Protection against overvoltage at the output (OVP)
Derating
> 55 °C (1 kW/K)
> 55 °C (3.2 A/K)
Control deviation
± 0.2 % (Input voltage change ±20 %)
< 0.5 % (Voltage deviation static load change 20% ... 100%)
< 1 % (Current deviation Static load change 20 % ... 100 %)
Overshoot behavior
± 3 % (Switch-on procedure)
Connection method
2x RJ45
Push-in connection
T-LOX knee lever connection
rigid
1.5 mm² ... 16 mm²
10 mm² ... 50 mm²
10 mm² (recommended)
25 mm² (recommended)
flexible
1.5 mm² ... 16 mm²
10 mm² (recommended)
16 mm² ... 50 mm²
25 mm² (recommended)
AWG
14 ... 4 (Cu)
3 (recommended)
7 (recommended)
8 ... 0 (Cu)
Stripping length
18 mm ... 20 mm (10 mm² ... 25 mm² = 18 mm, 35 mm² ... 50 mm² = 20 mm)
18 mm (rigid/flexible)
Termination resistor
120 Ω (Terminating the end device)
Number of power modules as CAN bus devices
Electrical isolation between input and output
Insulation voltage input/output
Insulation voltage input, output / housing
2121 V DC (Basic insulation)
Insulation voltage input, output/signal, communication
Insulation voltage signal, communication/housing
MTBF (IEC 61709, SN 29500)
Service life
70000 h (40 °C, fan)
90000 h (40°C, electrolytic capacitators)