MTTF
331 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
98 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
Maximum power dissipation for nominal condition
Protective circuit
Short-circuit/overload protection
Output current
≤ 2 A (typical)
4 A (Peak, for 20 ms, with 5 mm spacing)
Range
≤ 10 mm (at 60 °C)
≤ 12 mm (at 25 °C)
min. 0 mm
Wireless modules that can be connected
Frequency range
0.15 MHz ... 80 MHz (Test Level 3 - asymmetrical)
100 kHz ... 148.5 kHz (Power transmission)
80 MHz ... 1 GHz (Test Level 3)
Flammability rating according to UL 94
Other resistance
Resistant to welding splashes
Vibration resistance in accordance with EN 60068-2-6/IEC 60068-2-6
Operation: 5 g per spatial direction, 10 Hz ... 150 Hz, amplitude ±0.34 mm
Shock in accordance with EN 60068-2-27/IEC 60068-2-27
Operation: 30 g, 11 ms duration, half-sine shock pulse, three shocks per spatial direction
Continuous shock in accordance with EN 60068-2-27/IEC 60068-2-27
Operation: 10 g, 16 ms duration, half-sine shock pulse, 1,000 shocks per spatial direction
Degree of protection
IP65 (Manufacturer's declaration)
Ambient temperature (operation)
-20 °C ... 40 °C (in accordance with UL, observe derating)
-20 °C ... 60 °C (observe derating)
Ambient temperature (storage/transport)
Permissible humidity (operation)
Permissible humidity (storage/transport)
Air pressure (operation)
80 kPa ... 108 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)
66 kPa ... 108 kPa (up to 3500 m above sea level)
Certificate
CE-compliant
E238705
R-R-PCK-1234232
YG3P2AR
Identification
CSA C22.2 NO. 61010-1, 3rd Edition
CSA C22.2 NO. 61010-2-201:18, 2nd Edition
cUL 61010 Listed
UL 61010 Listed
UL 61010-1, 3rd Edition
UL 61010-2-201, 2nd Edition
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Standards/regulations
EN 55016-2-3
EN 60204-1 (PELV)
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
Comments
Class A, industrial applications
Criterion A
Criterion B
Input
± 0.5 kV (Test Level 1 - symmetrical)
± 1 kV (Test Level 2 - asymmetrical)
± 2 kV (Test Level 3 - asymmetrical)
output
± 1 kV (Test Level 2 - asymmetrical)
± 2 kV (Test Level 3 - asymmetrical)
Signal
± 1 kV (Test Level 2 - asymmetrical)
± 2 kV (Test Level 3 - asymmetrical)
Voltage
10 V (80% amplitude modulation with 1 kHz)