MTTF
239 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
81 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
Maximum power dissipation for nominal condition
Typical current consumption
≤ 195 mA (at 24 V DC, at 25 °C)
Protective circuit
Transient protection, polarity protection
Connection method
M12 female, D-coded
M12 male, A-coded
Note on the connection method
Auto negotiation and autocrossing, fast startup (FSU, <500 ms)
Typical bit error rate ≤10<sup>-12</sup>
Transmission length
100 m (shielded twisted pair)
Protocols supported
Protocol transparent: PROFINET, PROFINET IRT, PROFIsafe, EtherCAT®, Modbus/TCP, Powerlink, TSN, etc.
Switch-on time
< 450 ms (ETH Full Duplex operating mode)
Range
≤ 20 mm (at 65°C)
≤ 40 mm (at 25 °C)
min. 0 mm
Wireless modules that can be connected
Frequency range
0.15 MHz ... 80 MHz (Test Level 3 - asymmetrical)
57 GHz ... 64 GHz (Data transmission)
80 MHz ... 1 GHz (Test Level 3)
Flammability rating according to UL 94
Other resistance
Resistant to welding splashes
Vibration resistance in accordance with EN 60068-2-6/IEC 60068-2-6
Operation: 5 g per spatial direction, 10 Hz ... 150 Hz, amplitude ±0.34 mm
Shock in accordance with EN 60068-2-27/IEC 60068-2-27
Operation: 30 g, 11 ms duration, half-sine shock pulse, three shocks per spatial direction
Continuous shock in accordance with EN 60068-2-27/IEC 60068-2-27
Operation: 10 g, 16 ms duration, half-sine shock pulse, 1,000 shocks per spatial direction
Degree of protection
IP65 (Manufacturer's declaration)
Ambient temperature (operation)
-20 °C ... 65 °C (observe derating)
Ambient temperature (storage/transport)
Permissible humidity (operation)
Permissible humidity (storage/transport)
Air pressure (operation)
80 kPa ... 108 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)
66 kPa ... 108 kPa (up to 3500 m above sea level)
Certificate
4720B-DETHR
CE-compliant
E238705
R-R-PCK-1234232
YG3DETHR
Identification
006-001057
Class A
CSA C22.2 NO. 61010-1, 3rd Edition
CSA C22.2 NO. 61010-2-201:18, 2nd Edition
cUL 61010 Listed
UL 61010 Listed
UL 61010-1, 3rd Edition
UL 61010-2-201, 2nd Edition