Input voltage range
300 V DC ... 740 V DC
300 V DC ... 825 V DC
Derating
< 650 V DC ... 300 V DC (46 W/V)
> 55 °C (1 kW/K)
> 55 °C (3.2 A/K)
Nominal input voltage range
650 V DC ... 740 V DC
650 V DC ... 825 V DC
Input current
38 A (825 V DC)
48 A (650 V DC)
Inrush current limitation
Supply system configuration
Efficiency
> 95 % (P<sub>Out</sub> >50%)
> 99.5 % (>5 kW)
Power dissipation standby
Protection against overvoltage at the output (OVP)
Control deviation
± 0.2 % (Input voltage change ±20 %)
< 0.5 % (Voltage deviation static load change 20% ... 100%)
< 1 % (Current deviation Static load change 20 % ... 100 %)
Overshoot behavior
± 3 % (Switch-on procedure)
Identification
DC IN: + / - / PE
DC OUT: + / -
Connection method
2x RJ45
Push-in connection
T-LOX knee lever connection
rigid
1.5 mm² ... 16 mm²
10 mm² ... 50 mm²
10 mm² (recommended)
25 mm² (recommended)
flexible
1.5 mm² ... 16 mm²
10 mm² (recommended)
16 mm² ... 50 mm²
25 mm² (recommended)
rigid (AWG)
15 ... 5 (Cu)
4 (recommended)
7 (recommended)
8 ... 0 (Cu)
Stripping length
18 mm (rigid/flexible)
20 mm (10 mm² ... 25 mm² = 18 mm, 35 mm² ... 50 mm² = 20 mm)
Transmission speed
125 kbps (Default)
500 kbps
Termination resistor
120 Ω (Terminating the end device)
Number of power modules as CAN bus devices
Electrical isolation between input and output
Insulation voltage input/output
Insulation voltage input, output / housing
Insulation voltage input, output/signal, communication
Insulation voltage signal, communication/housing
MTBF (IEC 61709, SN 29500)
Service life
70000 h (40 °C, fan)
90000 h (40°C, electrolytic capacitators)
Volumetric flow
360 m³/h ()
360 m³/h (P<sub>Out</sub> = 100 %, 45 °C)
Overvoltage category (IEC 60664-1)