MTTF
508.3 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
69.1 Years (MIL-HDBK-217F standard, temperature 25°C, operating cycle 100%)
702.5 Years (Telcordia standard, temperature 25 °C, operating cycle 100 % (7 days a week, 24 hours a day))
Maximum power dissipation for nominal condition
Typical current consumption
Voltage output signal
12 V DC ... 48 V DC (depending on the input voltage)
Connection method
Push-in spring connection
RJ45 jack, shielded
SC simplex
Single conductor/terminal point, rigid
Single-wire/terminal point, flexible
Conductor cross-section, flexible [AWG]
Transmit capacity, minimum
Transmit capacity, maximum
Transmission length incl. 3 dB system reserve
Wavelength
1310 nm (receive)
1550 nm (transmit)
Minimum receiver sensitivity
Maximum receiver sensitivity
Transmission medium
Copper
Multi-mode fiberglass
Transmission length
100 m (shielded twisted pair)
Signal LEDs
LNK/ACT, SPD, Err, US, US2
Material (Housing)
Aluminum
Polyamide fiberglass reinforced
Fiber types
50/125 µm
62.5/125 µm
Fiberglass
Vibration resistance in accordance with EN 60068-2-6/IEC 60068-2-6
Operation: 5g, 150 Hz, Criterion 3
Shock in accordance with EN 60068-2-27/IEC 60068-2-27
Operation: 30g, 11 ms half-sine shock pulse
Ambient temperature (operation)
Ambient temperature (storage/transport)
Altitude
≤ 2000 m (in acc. with UL)
Permissible humidity (operation)
10 % ... 95 % (non-condensing)
Shock
300 m/s², 11 ms (IEC 60068-2)
Certificate
CE-compliant
IECEx UL 25.0019X
UL 25 ATEX 3348X
Identification
Class I, Division 2, Groups A, B, C, and D, T4
Class I, Zone 2, IIC T4
Ex ec IIC T4 Gc
II 3 G Ex ec IIC T4 Gc
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU