MACX-MR-PH-690 Monitoring relay
N
0%
1336404

MACX-MR-PH-690 Monitoring relay

Manufactured by
Brand PHOENIX CONTACT
3-phase voltage monitoring relay, 24 V AC/DC … 240 V AC/DC wide range power supply, monitoring for phase sequence, phase failure and asymmetry (with adjustable asymmetry and response delay). It can be configured using smart phone app via NFC wireless communication function, 1x2 PDT dry contact outputs, closed circuit principle, auto reset, optional screw connection and plug-in connection.
4063151636623
only
available
100+
130
pcs.
(2026-08-29)
Supply from Phoenix Contact’s warehouse
Product recommended retail price (RRP) is
000
11100 0 € pcs.
All prices without tax
All prices with tax
inquiry
only
available
100+
inquiry
0
2026-08-29
pcs.
Properties
Description
Dimensions
Files
Codes
Mounting type
DIN rail mounting
Product type
Phase monitoring relay
Operating mode
Closed circuit
Mechanical service life
approx. 3x 10<sup>7</sup> cycles
Overvoltage category
III
Pollution degree
3
Rated impulse withstand voltage
6 kV
Service life electrical
approx. 1x 10<sup>5</sup> cycles, resistive load 2000 V A
Maximum power dissipation for nominal condition
15 W
Mains type
3-phase
Rated insulation voltage
690 V
Electrical isolation
300 V
Supply voltage range
24 V AC/DC ... 240 V AC/DC 15 % ... +10 %
Nominal power consumption
15 VA (1.5 W)
Frequency range
48 Hz ... 400 Hz
Input name
Measuring input
Measured value
AC sine (48 Hz ... 63 Hz)
Input resistance of voltage input
1 MΩ
Maximum temperature coefficient
0.05 %/K
Setting range for response delay
0 s ... 99.9 s
Min setting range of the voltage threshold value
160 V
Max. setting range of the voltage threshold value
690 V
Function
Asymmetry
Phase failure
Phase sequence
Basic accuracy
1 %
Repeat accuracy
0.5 %
Asymmetry
2 % ... 30 % / OFF
Voltage influence
0.5 %
Recovery time
200 ms
Contact switching type
2 floating changeover contacts
Maximum switching voltage
250 V AC
Interrupting rating (ohmic load) max.
2000 VA (8 A/250 V AC)
Output fuse
10 A (fast-blow)
Connection method
Screw connection
Stripping length
10 mm
Conductor cross-section rigid
0.2 mm² ... 2.5 mm²
Conductor cross-section flexible
0.2 mm² ... 2.5 mm²
Conductor cross-section AWG
24 ... 14
Tightening torque
0.5 Nm ... 0.6 Nm (5 lb in ... 7 lb in)
Width
22.5 mm
Height
109 mm
Depth
114 mm
Flammability rating according to UL 94
V0
Housing insulation material
PBT
Degree of protection
IP20 (Connection terminal blocks)
IP40 (Housing)
Ambient temperature (operation)
-25 °C ... 70 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Altitude
2000 m
Permissible humidity (operation)
10 % ... 95 %
Identification
CE-compliant
GB/T 14048.5
UL/C-UL Listed UL 508
Electromagnetic compatibility
Conformance with EMC directive
Length
0
m
Width
0
m
Height
0
m
Weight Net
0
kg
Weight
0
kg
Package
0
kg
Volume
0
No files found
ECLASS-13.0
27371803
ECLASS-15.0
27371803
ETIM 10.0
EC001441
GTIN
4063151636623
Item accessories
No item accessories found
No related items found