AXL P EX IS RTD8 1F Temperature module
N
0%
1397157

AXL P EX IS RTD8 1F Temperature module

Manufactured by
Brand PHOENIX CONTACT
Axioline P, Temperature recording module, Analog inputs: 8 (for resistance temperature detectors), connection technology: 2-, 3-, 4-conductor (shielded), transmission speed in the local bus: 100 Mbps, RTD functionality, intrinsically safe, degree of protection: IP20, including bus base module and Axioline P connectors
4063151781941
only
available
100+
35
pcs.
(2026-08-29)
Supply from Phoenix Contact’s warehouse
Product recommended retail price (RRP) is
000
108780 0 € pcs.
All prices without tax
All prices with tax
inquiry
only
available
100+
inquiry
0
2026-08-29
pcs.
Properties
Description
Dimensions
Files
Codes
Test voltage: 5 V supply of the local bus (UBus) / functional ground
500 V AC, 60 Hz, 1 min
Width
53.6 mm
Height
126.1 mm
Test voltage: 5 V supply of the local bus (UBus) / analog inputs
1500 V AC, 60 Hz, 1 min
Depth
77.1 mm
Max. output voltage Uo
10.6 V
Max. output current Io
16.8 mA
Note on dimensions
The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).
EMC note
EMC: class A product, see manufacturer's declaration in the download area
Max. output power Po
45 mW
Color (Housing)
gray (RAL 7042)
Safety-related maximum voltage Um
250 V
A, B / IIC: Max. external inductivity Lo / Max. external capacitance Co
100 mH / 2.3 µF
Number of interfaces
2
C/IIB, IIIC: Max. external inductivity Lo / Max. external capacitance Co
100 mH / 16.2 µF
Connection method
Bus base module
Push-in connection
D/IIA, E, F, G, Class III: Max. external inductivity Lo / Max. external capacitance Co
100 mH / 72 µF
Transmission speed
100 Mbps
Input address area
16 Byte
Output address area
0 Byte
Input name
Analog inputs
Description of the input
Inputs for resistive temperature sensors
Number of inputs
8 (for resistance temperature detectors)
Connection technology
2-, 3-, 4-conductor (shielded)
A/D converter resolution
24 bit
Sensor types (RTD) that can be used
Pt, Ni, KTY, Cu sensors
Tolerance, relative
see tables for tolerance values
Tolerance, absolute
see tables for tolerance values
typ. ± 0.1 K (Pt 100 with 3-wire connection)
Data formats
Inline, S7-compatible, standard formatting
Measured value representation
16 bits (15 bits + sign bit)
Input filter time
100 ms
120 ms (adjustable)
40 ms
60 ms
Nominal value of the current sources
1 mA (Pt 100, Ni 100, R<sub>Lin</sub> 500 Ω; pulse current, the specification is valid during the sampling phase)
10 µA (R<sub>Lin</sub> 10000 Ω; pulse current, the specification is valid during the sampling phase)
210 µA (Pt 1000, Ni 1000, R<sub>Lin</sub> 5000 Ω; pulse current, the specification is valid during the sampling phase)
Differential non-linearity
typ. 1 ppm ±0.0001 % (in all ranges)
Integral non-linearity
typ. 20 ppm ±0.02 % (R<sub>Lin</sub> 500 Ω)
typ. 200 ppm ±0.02 % (R<sub>Lin</sub> 5000 Ω)
typ. 30 ppm ±0.003 % (Pt 100)
typ. 800 ppm ±0.08 % (R<sub>Lin</sub> 10000 Ω)
Linear resistance measuring range
0 kΩ ... 10 kΩ
0 kΩ ... 5 kΩ
0 Ω ... 500 Ω
Process data update
1 ms
Protective circuit
Reverse polarity protection; Polarity protection diode
Short-circuit protection
Surge protection; electronic (35 V, 0.5 s)
Transient protection; Suppressor diode
Product type
I/O component
Product family
Axioline P
Type
block modular
Mounting position
any (no temperature derating)
Scope of supply
including bus base module and Axioline P connectors
Special properties
intrinsically safe
RTD functionality
Overvoltage category
II (IEC 60664-1, EN 60664-1)
Pollution degree
2 (IEC 60664-1, EN 60664-1)
Maximum power dissipation for nominal condition
1.44 W
Supply voltage
24 V DC (via bus base module)
5 V DC (via bus base module)
Supply voltage range
19.2 V DC ... 30 V DC
Current draw
max. 135 mA
max. 40 mA (via bus base module)
typ. 110 mA
typ. 30 mA (via bus base module)
Test voltage: 5 V supply of the local bus (U&lt;sub&gt;Bus&lt;/sub&gt;) / functional ground
500 V AC, 60 Hz, 1 min
Length
0
m
Width
0
m
Height
0
m
Weight Net
0
kg
Weight
0
kg
Package
0
kg
Volume
0
No files found
ECLASS-13.0
27242601
ECLASS-15.0
27242601
ETIM 10.0
EC001596
UNSPSC 21.0
32151600
GTIN
4063151781941
Item accessories
0%
AXL SHIELD SET Shield connection
N
2700518 AXL SHIELD SET Shield connection
4330 0 €
only
available
100+
inquiry
0
2026-08-29
pcs.
0%
ZB 20,3:UNPRINTED Zack marker strip
N
0820248 ZB 20,3:UNPRINTED Zack marker strip
069 0 €
only
available
100+
inquiry
0
2026-08-29
pcs.
0%
ZBF 10/5,8 AXL UNPRINTED Zack Marker strip, flat
N
0829580 ZBF 10/5,8 AXL UNPRINTED Zack Marker strip, flat
062 0 €
only
available
100+
inquiry
0
2026-09-12
pcs.
0%
EMT (35X46)R Insert label
N
0801604 EMT (35X46)R Insert label
50490 0 €
only
available
100+
inquiry
0
2026-09-13
pcs.
0%
AXL F/P IO EX PP Separating plate
N
1100201 AXL F/P IO EX PP Separating plate
490 0 €
only
available
100+
inquiry
0
2026-08-29
pcs.
0%
AXL P BS F2 Bus connector
N
1052428 AXL P BS F2 Bus connector
43630 0 €
only
available
100+
inquiry
0
2026-08-29
pcs.
No related items found