Assembly note
<b>NOTE:</b> Observe the permissible bending radii when routing cables, since the degree of protection may be at risk if the bending forces are too high. Reduce mechanical loads upstream of the connector, e.g., by using cable ties.
If the conductor is to be reconnected, it must be cut off above the last contact point.
Connection method
Insulation displacement connection
Frequency of connections between conductors of the same cross section
Structure of individual litz in acc. with VDE 0295 / smallest wire diameter
Wrench size, contact carrier
Wire diameter including insulation
Contact | Color (signal designation) | Contact (optional)
1 = WHOG (TD+)
2 = WHGN (RD+)
3 = OG (TD-)
4 = GN (RD-)
Nominal voltage U<sub>N</sub>
Nominal current I<sub>N</sub>
Transmission characteristics (category)
Flammability rating according to UL 94
Material of grip body
Zinc die-cast, nickel-plated
Material for screw connection
Zinc die-cast, nickel-plated
Signal type/category
Ethernet CAT5 (IEC 11801), 100 Mbps
Ambient temperature (operation) (male connector/female connector)
Ambient temperature (assembly)
Standards/specifications
according to IEC 61076-2-101
EN 50155:2001