Note for Canada
These products have not been evaluated for use in Canada per the relevant wireless regulations. Further evaluation is required for these products if they are installed or operated in Canada.
MTTF
110 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
191 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
53 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
Maximum power dissipation for nominal condition
3.84 W (at 24 V DC, at 25 °C)
Typical current consumption
≤ 160 mA (at 24 V DC, at 25 °C)
Inrush current
0.4 A (for 0.2 ms at 24 V DC, without remote coupler)
Protective circuit
Transient protection, polarity protection
Connection method
M12 connector, L-coded
M12 female, D-coded
Push-pull fast connection or screw connection
Note on the connection method
Autonegotiation and autocrossing, fast startup (FSU, < 500 ms), LFPT
Typical bit error rate ≤10-12
Transmission length
100 m (shielded twisted pair)
Protocols supported
Protocol transparent: PROFINET, PROFINET IRT, PROFIsafe, EtherCAT®, Modbus/TCP, Powerlink, TSN, etc.
Range
≤ 100 mm (can be set via DIP switches)
min. 0 mm
Center offset
± 20 mm (at 100 mm spacing between the devices)
± 5 mm (No spacing between the devices)
Wireless modules that can be connected
Frequency range
0.15 MHz ... 80 MHz (Test Level 3 - asymmetrical)
59 GHz ... 64 GHz (Data transmission)
80 MHz ... 1 GHz (Test Level 3)
Flammability rating according to UL 94
Other resistance
Resistant to welding splashes
Vibration resistance in accordance with EN 60068-2-6/IEC 60068-2-6
Operation: 5 g per spatial direction, 10 Hz ... 150 Hz, amplitude ±0.34 mm
Shock in accordance with EN 60068-2-27/IEC 60068-2-27
Operation: 30 g, 11 ms duration, half-sine shock pulse, three shocks per spatial direction
Continuous shock in accordance with EN 60068-2-27/IEC 60068-2-27
Operation: 10 g, 16 ms duration, half-sine shock pulse, 1,000 shocks per spatial direction
Degree of protection (IP)
IP65/IP66 (Manufacturer's declaration)
Degree of protection (IK)
IK06 (Impact resistance level)
Ambient temperature (operation)
-20 °C ... 65 °C (observe derating)
Ambient temperature (storage/transport)
Permissible humidity (operation)
Permissible humidity (storage/transport)
Air pressure (operation)
80 kPa ... 108 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)
66 kPa ... 108 kPa (up to 3500 m above sea level)
Certificate
CE-compliant
E238705
YG32000R
Note
From production batch 01
RED 2014/53/EU
Identification
UL 61010 Listed
UL 61010-1, 3rd Edition
UL 61010-2-201, 2nd Edition