Note for Canada
These products have not been evaluated for use in Canada per the relevant wireless regulations. Further evaluation is required for these products if they are installed or operated in Canada.
MTTF
112 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
221 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
51 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
Maximum power dissipation for nominal condition
1.3 W (Coupled, without load, with 5 mm spacing, at 24 V DC, at 25°C)
Protective circuit
Short-circuit/overload protection
Output current
≤ 2 A (typical)
≤ 4 A (typical, parallel operation)
4 A (Peak, for 20 ms, with 5 mm spacing)
6.8 A (Parallel operation, peak, for 20 ms, with 5 mm spacing)
Connection method
M12 female connector, L-coded
Wireless modules that can be connected
Frequency range
0.15 MHz ... 80 MHz (Test Level 3 - asymmetrical)
110 kHz ... 148.5 kHz (Power transmission)
80 MHz ... 1 GHz (Test Level 3)
Test field strength
~ 1.95 µA/m (within 10 m distance)
Output power
100 W (Communications power, for parallel operation with NEARFI 2200)
50 W (2x 50 W, communications power and actuator supply electrically isolated, for parallel operation with NEARFI 300)
50 W (Communications power)
Flammability rating according to UL 94
Other resistance
Resistant to welding splashes
Vibration resistance in accordance with EN 60068-2-6/IEC 60068-2-6
Operation: 5 g per spatial direction, 10 Hz ... 150 Hz, amplitude ±0.34 mm
Shock in accordance with EN 60068-2-27/IEC 60068-2-27
Operation: 30 g, 11 ms duration, half-sine shock pulse, three shocks per spatial direction
Continuous shock in accordance with EN 60068-2-27/IEC 60068-2-27
Operation: 10 g, 16 ms duration, half-sine shock pulse, 1,000 shocks per spatial direction
Degree of protection (IP)
IP65/IP66 (Manufacturer's declaration)
Degree of protection (IK)
IK06 (Impact resistance level)
Ambient temperature (operation)
-20 °C ... 40 °C (in accordance with UL, observe derating)
-20 °C ... 55 °C (observe derating)
Ambient temperature (storage/transport)
Permissible humidity (operation)
Permissible humidity (storage/transport)
Air pressure (operation)
80 kPa ... 108 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)
66 kPa ... 108 kPa (up to 3500 m above sea level)
Certificate
CE-compliant
E238705
YG3200R
Note
From production batch 01
RED 2014/53/EU
Identification
UL 61010 Listed
UL 61010-1, 3rd Edition
UL 61010-2-201, 2nd Edition
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Standards/regulations
EN 55016-2-3
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
Comments
Class A, industrial applications
Criterion A
Criterion B
Input
± 0.5 kV (Test Level 1 - symmetrical)
± 1 kV (Test Level 2 - asymmetrical)
± 2 kV (Test Level 3 - asymmetrical)