Flammability rating according to UL 94
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material for screw connection
Zinc die-cast, nickel-plated
Nominal voltage U<sub>N</sub>
Nominal current I<sub>N</sub>
Insertion/withdrawal cycles
Type
free cable end
Plug angled M12
Note
Due to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments.
Cable type
Gray, highly flexible PUR [800]
Conductor structure signal line
Conductor cross-section
4x 0.34 mm² (Signal line)
Wire diameter incl. insulation
1.3 mm ±0.05 mm (Signal line)
Single wire, color
brown, white, blue, black
Max. conductor resistance
Minimum bending radius, fixed installation
Minimum bending radius, flexible installation
Smallest bending radius, fixed installation
Smallest bending radius, movable installation
Dynamic load capacity (bending)
Max. bending cycles: 15000000, Bending radius: 50 mm, Traversing path: 0.9 m, Traversing rate: 5 m/s, Acceleration: 30 m/s²
Dynamic load capacity (torsion)
Torsion: ±360 °/m, Torsion cycles: 1000000, Torsional frequency: 35 cycles/min.