Ambient temperature (storage/transport)
Signal type/category
Ethernet CAT6<sub>A</sub> (IEC 11801:2002)
Ethernet CAT6<sub>A</sub> (IEC 11801:2002), 10 Gbps
Type
RJ45 Plug, straight, 8-position
Insertion/withdrawal cycles
Insertion force
30 N (per signal contact)
Withdrawal force
50 N (per signal contact)
Flammability rating according to UL 94
Ambient temperature (operation)
-20 °C ... 80 °C
-20 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (Cable, flexible installation)
Cable type
Ethernet, Type B, 8-pos., CAT5, LSZH [BC5]
Conductor structure signal line
Wire diameter incl. insulation
Single wire, cross section [AWG]
Minimum bending radius, fixed installation
Smallest bending radius, fixed installation
Near end crosstalk attenuation (NEXT)
35.3 dB (at 100 MHz)
38.4 dB (at 62.5 МHz)
42.9 dB (at 31.25 МHz)
45.8 dB (at 20 МHz)
47.2 dB (at 16 MHz)
50.3 dB (at 10 MHz)
56.3 dB (at 4 МHz)
65.3 dB (with 1 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
32.3 dB (at 100 MHz)
35.4 dB (at 62.5 МHz)
39.9 dB (at 31.25 МHz)
41.3 dB (at 25 MHz)
42.8 dB (at 20 МHz)
44.2 dB (at 16 MHz)
47.3 dB (at 10 MHz)
48.8 dB (at 8 МHz)
53.3 dB (at 4 МHz)
62.3 dB (with 1 MHz)
Return attenuation (RL)
19 dB (at 100 MHz)
20 dB (with 1 MHz)
20.7 dB (at 62.5 МHz)
23 dB (at 4 МHz)
23.3 dB (at 31.25 МHz)
24.2 dB (at 25 MHz)
24.5 dB (at 8 МHz)
25 dB (at 10 MHz)
25 dB (at 16 MHz)
25 dB (at 20 МHz)
Shield attenuation
12.07 dB (at 16 MHz)
13.54 dB (at 20 МHz)
17.11 dB (at 31.25 МHz)
24.76 dB (at 62.5 МHz)
3.2 dB (with 1 MHz)
31.99 dB (at 100 MHz)
6.01 dB (at 4 МHz)
9.49 dB (at 10 MHz)
Halogen-free
complying with IEC 60754-1/2
Flame resistance
IEC 60332-1-2
IEC 60332-1-2/IEC 60332-3-24/CM
Ambient temperature (installation)