Flammability rating according to UL 94
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material for screw connection
Zinc die-cast, nickel-plated
Nominal voltage U<sub>N</sub>
Nominal current I<sub>N</sub>
Type
free cable end
Socket straight M8
Cable type
PUR irradiated halogen-free orange [150]
Conductor structure signal line
Conductor cross-section
4x 0.34 mm² (Signal line)
Wire diameter incl. insulation
1.05 mm ±0.05 mm (Signal line)
Single wire, color
brown, white, blue, black
Length of twist, overall twist
Max. conductor resistance
Test voltage
2500 V (50 Hz, 5 minutes)
Smallest bending radius, fixed installation
Smallest bending radius, movable installation
Dynamic load capacity (bending)
Dynamic load capacity (torsion)
Halogen-free
The cable is halogen-free
Other resistance
hydrolysis and microbe resistant
Resistant to welding splashes
Ambient temperature (operation)
-25 °C ... 90 °C (Plug / socket)
-40 °C ... 105 °C (Cable, flexible installation)
-50 °C ... 105 °C (cable, fixed installation)