Ambient temperature (operation) (Cable, fixed installation)
-20 °C ... 80 °C (cable, fixed installation)
0 °C ... 50 °C (for installation)
Ambient temperature (operation) (male connector/female connector)
-20 °C ... 70 °C (RJ45)
-25 °C ... 90 °C (Plug / socket)
Insulation resistance
≥ 100 MΩ
5 GΩ*km (Data cable)
Nominal voltage U<sub>N</sub>
Nominal current I<sub>N</sub>
Insertion/withdrawal cycles
Flammability rating according to UL 94
Type
Plug straight RJ45
Socket straight M12
Material
CuSn (Contact)
CuZn (Contact)
NBR
Ni/Au (Contact surface)
PA (Housing)
PC (Contact carrier)
TPU GF
TPU, hardly inflammable, self-extinguishing
Zinc die-cast, nickel-plated
Conductor structure
1x2xAWG22/19 + 1x4xAWG24/19
Conductor structure signal line
Conductor structure, voltage supply
Conductor cross-section
2x 0.38 mm² (Power supply)
4x 0.25 mm² (Signal line)
Wire diameter incl. insulation
1.35 mm (Signal line)
1.5 mm (Power supply)
Single wire, color
brown, blue, white/orange, white/green, green, orange
Type of pair shielding
Tinned copper braided shield, 95 % covering
Overall twist
1 star quad and 2 wires with 2 fillers
Max. conductor resistance
Nominal voltage, cable
125 V (Data cable)
48 V (Power supply)
Test voltage
2000 V (Power supply)
max. 700 V AC (Data cable)
Smallest bending radius, fixed installation