Inrush current integral (I2t)
Supply system configuration
Nominal input voltage range
Setting range of the output voltage (USet)
48 V DC ... 57 V DC (> 48 V DC, constant capacity restricted)
Nominal output current (IN) (IN_PMax)
max. 5 A (P<sub>N </sub>= 240 W)
Typical national grid voltage
Nominal output current (IN) (IN_PMin)
max. 4.2 A (P<sub>N </sub>= 200 W)
Voltage type of supply voltage
Output power (PN)
200 W (100 V AC)
240 W (240 V AC)
Inrush current integral (I<sup>2</sup>t)
Frequency range (f<sub>N</sub>)
Mains buffering time
typ. 20 ms (120 V AC)
typ. 30 ms (230 V AC)
Current consumption
max. 2.5 A (200 W)
max. 3 A (240 W)
typ. 1.2 A (240 V AC (240 W))
typ. 2.3 A (109 V AC (200 W))
typ. 2.4 A (100 V AC (200 W))
typ. 2.4 A (110 V AC (240 W))
Protective circuit
Transient protection; Varistor
Device mains fuse
5 A internal (device protection), fast-blow
Recommended breaker for input protection
10 A ... 16 A (Characteristic B, C, D, K or comparable)
Efficiency
typ. 93 % (120 V AC)
typ. 94 % (230 V AC)
Setting range of the output voltage (U<sub>Set</sub>)
48 V DC ... 57 V DC (> 48 V DC, constant capacity restricted)
Nominal output current (I<sub>N</sub>) (IN_PMax)
max. 5 A (P<sub>N </sub>= 240 W)
Nominal output current (I<sub>N</sub>) (IN_PMin)
max. 4.2 A (P<sub>N </sub>= 200 W)
Crest factor
typ. 1,7 (120 V AC)
typ. 1.8 (230 V AC)
Output power (P<sub>N</sub>)
200 W (100 V AC)
240 W (240 V AC)
Connection in parallel
yes, for increasing power and redundancy with diode
Connection in series
yes, for increased output voltage
Feedback voltage resistance
Protection against overvoltage at the output (OVP)
Residual ripple
typ. 200 mV<sub>PP</sub> (with nominal values)
Control deviation
< 0.1 % (change in input voltage ±10 %)
< 0.3 % (change in load, static 10 % ... 90 %)
< 1.5 % (change in load, dynamic 10 % ... 90 %)
Rise time
< 100 ms (U<sub>Out</sub> = 10 % ... 90 %)
Minimum no-load power dissipation
Maximum no-load power dissipation
Minimum nominal load power dissipation
Power loss nominal load max.
Integrated fuse protection
Identification
1.1 (), 1.2 (L), 1.3 (N)
2.1, 2.2 (+), 2.3, 2.4 (-)
CB scheme (IEC 61010-1, IEC 61010-2-201)
UL/C-UL Listed UL 61010-1
UL/C-UL Listed UL 61010-2-201
rigid
0.5 mm² ... 2.5 mm²
1.5 mm² ... 2.5 mm²
flexible
0.5 mm² ... 2.5 mm²
1.5 mm² ... 2.5 mm²
flexible with ferrule without plastic sleeve
0.5 mm² ... 2.5 mm²
1.5 mm² ... 2.5 mm²
flexible with ferrule with plastic sleeve
0.5 mm² ... 2.5 mm²
1.5 mm² ... 2.5 mm²
rigid (AWG)
16 ... 14 (Cu)
18 ... 14 (Cu)