Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os)
Test voltage: 5 V supply of the local bus (UBus) / functional ground
Note on dimensions
The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).
Note
The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).
EMC note
EMC: class A product, see manufacturer's declaration in the download area
Connection method
Bus base module
Card edge connector
Push-in connection
Mounting position
Panel mounting on horizontal or vertical DIN rail
Special properties
6 slots for Axioline Smart Elements
with maritime approval
Overvoltage category
II (IEC 60664-1, EN 60664-1)
Pollution degree
2 (IEC 60664-1, EN 60664-1)
Maximum power dissipation for nominal condition
Supply voltage
24 V DC
3.3 V DC (using card edge connectors)
5 V DC
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw
max. 12 A (Applications with UL approval, external fusing)
max. 16 A (provide external protection)
Current consumption
min. 1.5 mA (without connected Smart Elements, with nominal voltage)
Protective circuit
Surge protection; Suppressor diode
Protection
max. 12 A (Applications with UL approval)
max. 16 A
Test voltage: 5 V supply of the local bus / 24 V supply (I/Os)
Test voltage: 5 V supply of the local bus (U<sub>Bus</sub>) / functional ground
Test voltage: 24 V supply (I/O) / functional ground
Connection name
I/O supply feed-in (U<sub>P</sub>)
Note on the connection method
Please observe the information provided on conductor cross-sections in the “Axioline F: system and installation” user manual.
Conductor cross-section, rigid
Conductor cross-section, flexible
Conductor cross-section AWG
Ambient temperature (operation)
Air pressure (operation)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)
Permissible humidity (operation)
5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)
5 % ... 95 % (non-condensing)
Vibration resistance in accordance with EN 60068-2-6/IEC 60068-2-6
Shock in accordance with EN 60068-2-27/IEC 60068-2-27
Continuous shock in accordance with EN 60068-2-27/IEC 60068-2-27
Protection class
III (IEC 61140, EN 61140, VDE 0140-1)