Tightening torque
0.2 Nm (M8 connectors)
0.4 Nm (M12 connector)
Flammability rating according to UL 94
Material for screw connection
Zinc die-cast, nickel-plated
Insulation resistance
≥ 100 GΩ*km (at 20 °C)
≥ 100 MΩ
Nominal voltage U<sub>N</sub>
Nominal current I<sub>N</sub>
Insertion/withdrawal cycles
Type
Plug straight M12
Socket straight M8
UL AWM Style
20549 / 10493 (80°C/300 V)
Cable type
PUR halogen-free black [PUR]
Conductor structure signal line
Conductor cross-section
3x 0.25 mm² (Signal line)
Wire diameter incl. insulation
Thickness, insulation
≥ 0.21 mm (Core insulation)
Length of twist, overall twist
Max. conductor resistance
Smallest bending radius, fixed installation
Smallest bending radius, movable installation
Dynamic load capacity (bending)
Dynamic load capacity (torsion)
Torsion: ±180 °/m, Torsion cycles: ≥5000000, Torsional frequency: 35 cycles/min.
Halogen-free
in accordance with DIN VDE 0472 part 815