Assembly note
<b>NOTE:</b> Observe the permissible bending radii when routing cables, since the degree of protection may be at risk if the bending forces are too high. Reduce mechanical loads upstream of the connector, e.g., by using cable ties.
Max. operating voltage Umax
Note on application
Unused slots are to be sealed off prior to commissioning. Suitable sealing elements are to be found under "Accessories".
Application
Standard, extended requirements
Max. operating voltage U<sub>max</sub>
Nominal voltage U<sub>N</sub>
Max. current carrying capacity per path
Current carrying capacity per slot
Slot/position = Wire color or connection
1 / 4 (A) = WH
1-8 / 1 (+ 24 V) = BN
1-8 / 3 (0 V) = BU
1-8 / 5 (PE) = GNYE
2 / 4 (A) = GN
3 / 4 (A) = YE
4 / 4 (A) = GY
5 / 4 (A) = PK
6 / 4 (A) = RD
7 / 4 (A) = BK
8 / 4 (A) = VT
Material Molding compound
Flammability rating according to UL 94
Conductor structure signal line
Conductor structure, voltage supply
Conductor cross-section
3x 0.75 mm² (power line)
8x 0.34 mm² (Signal line)
Wire diameter incl. insulation
1.3 mm ±0.1 mm (Signal line)
1.8 mm ±0.1 mm (power line)
Single wire, color
brown, blue, green/yellow, white, green, yellow, gray, pink, red, black, violet
Max. conductor resistance
≤ 26 Ω/km (power line)
≤ 53 Ω/km (Signal line)
Minimum bending radius, fixed installation
Minimum bending radius, flexible installation