Cable type
Ethernet, Type B, 8-pos., CAT6A, LSZH [BC6A]
Conductor structure signal line
Wire diameter incl. insulation
Single wire, cross section [AWG]
Test voltage Core/Shield
1010.00 V AC
1500.00 V DC
Minimum bending radius, fixed installation
Smallest bending radius, fixed installation
Near end crosstalk attenuation (NEXT)
34.8 dB (at 500 MHz)
36.3 dB (at 400 MHz)
38.1 dB (at 300 MHz)
40.8 dB (at 200 MHz)
45.3 dB (at 100 MHz)
48.4 dB (at 62.5 МHz)
52.9 dB (at 31.25 МHz)
55.8 dB (at 20 МHz)
57.2 dB (at 16 MHz)
60.3 dB (at 10 MHz)
66.3 dB (at 4 МHz)
75 dB (with 1 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
31.8 dB (at 500 MHz)
33.3 dB (at 400 MHz)
35.1 dB (at 300 MHz)
37.8 dB (at 200 MHz)
42.3 dB (at 100 MHz)
45.4 dB (at 62.5 МHz)
49.9 dB (at 31.25 МHz)
51.3 dB (at 25 MHz)
52.8 dB (at 20 МHz)
54.2 dB (at 16 MHz)
57.3 dB (at 10 MHz)
58.8 dB (at 8 МHz)
63.3 dB (at 4 МHz)
72.3 dB (with 1 MHz)
Return attenuation (RL)
15.6 dB (at 300 MHz)
15.6 dB (at 400 MHz)
15.6 dB (at 500 MHz)
16.4 dB (at 200 MHz)
19 dB (at 100 MHz)
20 dB (with 1 MHz)
20.7 dB (at 62.5 МHz)
23 dB (at 4 МHz)
23.3 dB (at 31.25 МHz)
24.2 dB (at 25 MHz)
24.5 dB (at 8 МHz)
25 dB (at 10 MHz)
25 dB (at 16 MHz)
25 dB (at 20 МHz)
Shield attenuation
11.2 dB (at 16 MHz)
12.6 dB (at 20 МHz)
15.8 dB (at 31.25 МHz)
22.5 dB (at 62.5 МHz)
28.7 dB (at 100 MHz)
3.1 dB (with 1 MHz)
41.4 dB (at 200 MHz)
5.7 dB (at 4 МHz)
51.4 dB (at 300 MHz)
60.1 dB (at 400 MHz)
67.9 dB (at 500 MHz)
8.9 dB (at 10 MHz)
Halogen-free
complying with IEC 60754-1/2
Flame resistance
IEC 60332-1-2/IEC 60332-3-24/CM
Ambient temperature (operation)
-20 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (Cable, flexible installation)
Ambient temperature (installation)