CCCex note
Use in potentially explosive areas is not permitted in China.
MTTF
102 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
247 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
543 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
MTBF
400 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
64 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
Maximum power dissipation for nominal condition
Test voltage data interface/power supply
1.5 kV<sub>rms</sub> (50 Hz, 1 min.)
Supply voltage range
11 V DC ... 30 V DC (via pluggable COMBICON screw terminal block)
Typical current consumption
Max. current consumption
≤ 2 A (For operation in a joining station, via the DIN rail connector)
Status and diagnostic indicators
LEDs: VCC (supply voltage), NET (Mod/Net status), FO signal (fiber optic signal quality), ERR (broken fiber, fiber optic)
Minimum switching voltage
Maximum switching voltage
Signal
± 1 kV
± 2 kV
CAN
CANopen®
DeviceNet™
Transmit capacity, minimum
-14.6 dBm (62,5/125 µm)
-17.6 dBm (50/125 µm)
-4 dBm (200/230 µm)
Transmission protocol
Protocol transparent for CAN interface
Connection method
B-FOC (ST®)
COMBICON plug-in screw terminal block
Minimum receiver sensitivity
-28.1 dBm (200/230 µm)
-29 dBm (50/125 µm)
-29 dBm (62,5/125 µm)
Transmission medium
2-wire twisted pair, shielded
Multi-mode fiberglass
PCF fiber
Transmission speed
≤ 1 Mbps (Configurable via DIP switches)
Transmission length
≤ 5000 m (Dependent on the data rate and the protocol used)
Number of bus devices
≤ 128 (CANopen®, can be addressed logically)
≤ 63 (DeviceNet™, can be addressed logically)
≤ 64 (per potential segment)
Termination resistor
124 Ω (Integrated and ready to be switched)
Single conductor/terminal point, rigid
Single-wire/terminal point, flexible
Max. AWG conductor cross-section, flexible
Min. AWG conductor cross-section, flexible
Single-wire/terminal point, rigid AWG max.
Single-wire/terminal point, rigid AWG min.
Fiber types
200/230 µm
50/125 µm
62.5/125 µm
Fiberglass
PCF fiber
Vibration resistance in accordance with EN 60068-2-6/IEC 60068-2-6
Operation: 5g, 10...150 Hz, 2.5 h, in XYZ direction