EMC note
EMC: class A product, see manufacturer's declaration in the download area
Diagnostics messages
Configuration invalid Message in the diagnostic code (in the IB IL format)
Module faulty Message in the diagnostic code (in the IB IL format)
Short circuit Message in the diagnostic code (in the IB IL format)
Nominal voltage for I/O supply
24 V DC (This supply voltage is provided via the IO-Link interface of the IO-Link master.)
Nominal current for every IO-Link port
Current consumption
max. 135 mA
typ. 16.5 mA ±15 % (at 24 V DC)
Protective circuit
Overload protection
Reverse polarity protection
Short-circuit protection
Reverse polarity protection
Amount of process data
16 bit (Input data)
16 bit (Output data)
Load/output load voltage output
Permissible cable length
max. 30 m (Shielded cable)
Diagnostics
Configuration invalid
Module faulty
Short circuit
Message
Message in the diagnostic code (in the IB IL format)
Color (Housing)
anthracite gray (RAL 7016)
Ambient temperature (operation)
Air pressure (operation)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)
Permissible humidity (operation)
Permissible humidity (storage/transport)
Vibration resistance in accordance with EN 60068-2-6/IEC 60068-2-6
Operation: 2g
Storage/transport: 5g
Shock in accordance with EN 60068-2-27/IEC 60068-2-27
Operation: 30g, 11 ms, three shocks in each space direction
Storage/transport: 50g, 11 ms, three shocks in each space direction
Continuous shock in accordance with EN 60068-2-27/IEC 60068-2-27
10g, 16 ms, 1000 shocks, in all space directions
Protection class
III (IEC 61140, EN 61140, VDE 0140-1)
Mounting type
Screw mounting (M12 thread)