Typ. starting time with Us
< 200 ms (when controlled via A1)
Rated control circuit supply voltage US
24 V AC/DC ... 230 V AC/DC -15 % / +10 %
Rated control supply current IS
typ. 103 mA (24 V DC)
typ. 21 mA (230 V AC)
typ. 38 mA (110 V AC)
typ. 47 mA (48 V DC)
Application
Emergency stop
Light grid
Magnetic switch
Safety door
Transponder
Power consumption at US
2.7 W (with DC)
2.9 W (with AC)
Relay type
Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Overvoltage category
II, III (See the section “Insulation coordination”)
Typical response time
< 100 ms (manual, monitored start)
< 150 ms (automatic start)
Typ. starting time with U<sub>s</sub>
< 200 ms (when controlled via A1)
Response time
< 200 ms (When requested via A1; applicative deactivation via A1/A2 is not permitted)
Typical release time
< 20 ms (on demand via the sensor circuit)
Recovery time
< 500 ms (following demand of the safety function)
100 ms (Availability time after activating the sensor circuit during manual start)
Start pulse length
min. 500 ms (manual start)
Maximum power dissipation for nominal condition
17.3 W (at I<sub>L</sub>² = 72 A²)
Rated surge voltage/insulation
See data sheet, section “Insulation coordination”.
Rated control circuit supply voltage U<sub>S</sub>
24 V AC/DC ... 230 V AC/DC -15 % / +10 %
Rated control supply current I<sub>S</sub>
typ. 103 mA (24 V DC)
typ. 21 mA (230 V AC)
typ. 38 mA (110 V AC)
typ. 47 mA (48 V DC)
Power consumption at U<sub>S</sub>
2.7 W (with DC)
2.9 W (with AC)
Apparent power
typ. 5 VA (at U<sub>S</sub>)
Inrush current
< 5 mA (typically with U<sub>S</sub> at S10/S12/S13)
< 80 A (Δt = 50 µs at U<sub>s</sub>)
> -5 mA (typ. with U<sub>S</sub> at S22)
max. 6 A
min. 10 mA
typ. 10 mA (typ. with U<sub>S</sub> at S34/35, Δt = 330 ms)
Filter time
2 ms (at A1 in the event of voltage dips at U<sub>s</sub>)
max. 1.5 ms (Test pulse width of low test pulses)
Test pulse rate = 5 x Test pulse width
Protective circuit
275 V varistor / 411 V suppressor diode
Reverse polarity protection; 38.6 V suppressor diode
Description of the input
IEC 61131-2 Type 3 (S10, S12, S13)<br/>Current, inward (S10, S12, S13)<br/>Current, outward (S22)
non-safety-related
safety-related sensor inputs
Input voltage range "0" signal
0 V DC ... 5 V DC (for safe Off; at S10/S12/S13)
Input voltage range "1" signal
11 V DC ... 30 V DC (at S10/S12/S13)
19.2 V DC ... 30 V DC
Input current range "0" signal
0 mA ... 2 mA (for safe Off; at S10/S12/S13)
Max. permissible overall conductor resistance
Current consumption
typ. -2 mA (typ. with U<sub>S</sub> at S22)
typ. 1 mA (typ. with U<sub>S</sub> at S35)
typ. 2.5 mA (typ. with U<sub>S</sub> at S34)
typ. 4 mA (typically with U<sub>S</sub> at S10/S12/S13)
Output description
2 N/C contacts parallel, non-safety-related, floating
2 N/O contacts each in series, safety-related, floating
Contact switching type
1 signaling current path
3 enabling current paths
Switching voltage
max. 250 V AC/DC
min. 5 V AC/DC
Limiting continuous current
Sq. Total current
72 A<sup>2</sup> (observe derating)
Mechanical service life
10x 10<sup>6</sup> cycles