Test voltage: Ethernet interface 1 / 24 V communications voltage (UL) feed-in
Test voltage: Ethernet interface 2 / 24 V communications voltage (UL) feed-in
Test voltage: 24 V communications voltage (UL) feed-in / functional ground
Note on dimensions
The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).
Connection method
Bus base module
Micro USB type B (up to HW 04)
Push-in connection
RJ45 jack
USB type C (from HW 05)
Note on the connection method
Auto negotiation and autocrossing
Please observe the information provided on conductor cross-sections in the “Axioline F: system and installation” user manual.
Transmission speed
100 Mbps
100 Mbps (Full duplex)
Transmission physics
Ethernet in RJ45 twisted pair
System-specific protocols
Specification
Sercos specification 1.31
Number of supported devices
Number of local bus devices that can be connected
Mounting position
any (observe temperature derating)
Overvoltage category
II (IEC 60664-1, EN 60664-1)
Pollution degree
2 (IEC 60664-1, EN 60664-1)
Maximum power dissipation for nominal condition
Supply voltage
24 V DC
5 V DC (via bus base module)
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw
max. 570 mA (2.0 A at U<sub>Bus</sub>, U<sub>L</sub> = 24 V, up to HW 04)
max. 670 mA (2.5 A at U<sub>Bus</sub>, U<sub>L</sub> = 24 V, from HW 05)
Current consumption
typ. 105 mA (without I/O modules, U<sub>L</sub> = 24 V, up to HW 04)
typ. 85 mA (without I/O modules, U<sub>L</sub> = 24 V, from HW 05)
Protective circuit
Reverse polarity protection; electronic
Surge protection; electronic
Power supply unit
max. 2 A (up to HW 04)
max. 2.5 A (from HW 05)
Test voltage: Ethernet interface 1 / Ethernet interface 2
Test voltage: Ethernet interface 1 / 24 V communications voltage (U<sub>L</sub>) feed-in
Test voltage: Ethernet interface 2 / 24 V communications voltage (U<sub>L</sub>) feed-in
Test voltage: Ethernet interface 1 / functional ground
Test voltage: Ethernet interface 2 / functional ground
Test voltage: 24 V communications voltage (U<sub>L</sub>) feed-in / functional ground
Conductor cross-section, rigid
Conductor cross-section, flexible
Conductor cross-section AWG
Ambient temperature (operation)
-25 °C ... 55 °C (Mounting position: any)
-25 °C ... 60 °C (Mounting position: panel mounting on horizontal DIN rail)
Air pressure (operation)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)
70 kPa ... 106 kPa (up to 3000 m above sea level)