Typ. starting time with Us
< 150 ms (with U<sub>s</sub> when controlled via A1)
Rated control circuit supply voltage US
20.4 V DC ... 26.4 V DC
24 V DC -15 % / +10 %
Rated control supply current IS
Application
Ex
High demand
Low demand
Safe switch off
Diagnostic supply voltage UD
Input current at UD
6 mA (at the contacts 21/0V for U<sub>D</sub>; + 100 mA depending on load at contact 22)
Relay type
Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Inrush current at UD
typ. 200 mA (Δt < 1 ms; for contacts 21 - 0 V at U<sub>D</sub>)
Typ. starting time with U<sub>s</sub>
< 150 ms (with U<sub>s</sub> when controlled via A1)
Typical release time
< 30 ms (when controlled via A1)
Maximum power dissipation for nominal condition
3.28 W (I<sub>L</sub>² = 36 A²)
Rated surge voltage/insulation
Rated control circuit supply voltage U<sub>S</sub>
20.4 V DC ... 26.4 V DC
24 V DC -15 % / +10 %
Rated control supply current I<sub>S</sub>
Power consumption at U<sub>S</sub>
Inrush current
max. 100 mA
max. 6 A
min. 1 mA
min. 3 mA
typ. 150 mA (Δt < 5 ms at U<sub>s</sub>)
Filter time
≥ 50 ms (at A1-A2; low test pulse rate)
≥ 600 ms (at A1-A2; high test pulse rate)
max. 17 ms (at A1-A2; high test pulse width)
max. 3 ms (at A1-A2 in the event of voltage dips at U<sub>s</sub>)
max. 3 ms (at A1-A2; low test pulse width)
Diagnostic supply voltage U<sub>D</sub>
Input current at U
6 mA (at the contacts 21/0V for U<sub>D</sub>; + 100 mA depending on load at contact 22)
Inrush current at U<sub>D</sub>
typ. 200 mA (Δt < 1 ms; for contacts 21 - 0 V at U<sub>D</sub>)
Output description
2 N/O contacts in series, without delay, floating
Contact switching type
1 confirmation current path
1 enabling current path
Contact material
AgCuNi, + Au
AgSnO<sub>2</sub>
Switching voltage
max. 250 V AC/DC
max. 26.4 V DC
min. 12 V AC/DC
min. 20.4 V DC
Switching capacity
4 A (24 V (DC13))
5 A (250 V (AC15))
Limiting continuous current
100 mA
4 A (Low demand)
6 A (High demand)
Sq. Total current
36 A<sup>2</sup> (observe derating)
Mechanical service life
10x 10<sup>6</sup> cycles
Output fuse
150 mA Fast-blow
4 A gL/gG (for low-demand applications)
6 A gL/gG
Conductor cross-section rigid
Conductor cross-section flexible
Conductor cross-section AWG