Typ. starting time with Us
150 ms (when controlled via pins 05/06)
Rated control circuit supply voltage US
19.5 V DC ... 30 V DC
24 V DC -20 % / +25 %
Rated control supply current IS
Application
Ex
High demand
Low demand
Safe switch off
Diagnostic supply voltage UD
24 V DC -20 % / +25 % (at pin 04)
Input current at UD
7 mA (at pins 04/03 for U<sub>D</sub>; + 100 mA depending on load at pin 02)
Relay type
Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Inrush current at UD
typ. 200 mA (Δt < 1 ms; at pins 04/03 for U<sub>D</sub>)
Typ. starting time with U<sub>s</sub>
150 ms (when controlled via pins 05/06)
Typical release time
30 ms (when controlled via pins 05/06)
Maximum power dissipation for nominal condition
1.86 W (at U<sub>B</sub> = 30 V DC, U<sub>BD</sub> = 30 V DC, I<sub>L</sub> = 9 A²)
Rated surge voltage/insulation
Rated control circuit supply voltage U<sub>S</sub>
19.5 V DC ... 30 V DC
24 V DC -20 % / +25 %
Rated control supply current I<sub>S</sub>
Power consumption at U<sub>S</sub>
Inrush current
max. 100 mA
max. 3 A
min. 1 mA
min. 3 mA
typ. 100 mA (Δt < 50 ms at U<sub>s</sub>)
Filter time
≥ 50 ms (at pins 05/06; low test pulse width)
≥ 600 ms (at pins 05/06; high test pulse width)
max. 17 ms (at pins 05/06; high test pulse width)
max. 3 ms (at pins 05/06 in the event of voltage dips at U<sub>s</sub>)
max. 3 ms (at pins 05/06; low test pulse width)
Diagnostic supply voltage U<sub>D</sub>
24 V DC -20 % / +25 % (at pin 04)
Input current at U
7 mA (at pins 04/03 for U<sub>D</sub>; + 100 mA depending on load at pin 02)
Inrush current at U<sub>D</sub>
typ. 200 mA (Δt < 1 ms; at pins 04/03 for U<sub>D</sub>)
Protective circuit
Polarity reversal protection for rated control circuit supply voltage and diagnostic supply voltage
Surge protection; 35 V suppressor diode (pins 05/06)33 V suppressor diode (pins 04/03)35 V suppressor diode (pins 02/03)
Output description
Safety-related N/C contacts
safety-related N/O contacts
Contact switching type
1 confirmation current path
1 enabling current path
Contact material
AgCuNi, + Au
AgSnO<sub>2</sub>
Switching voltage
max. 230 V AC/DC
max. 30 V DC
min. 12 V AC/DC
min. 19.2 V DC
Switching capacity
3 A (230 V (AC15))
3 A (24 V (DC13))
Limiting continuous current
Sq. Total current
9 A<sup>2</sup> (observe derating)
Mechanical service life
10x 10<sup>6</sup> cycles
Output fuse
150 mA Fast-blow
3 A gL/gG
Connection method
Plug-in connection
Pluggable onto VIP base module
Status display
2 x LED bi-color (green, red)