CCCex note
Use in potentially explosive areas is not permitted in China.
MTTF
172 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
418 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
942 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
MTBF
113 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
549 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
Maximum power dissipation for nominal condition
Test voltage data interface/power supply
1.5 kV<sub>rms</sub> (50 Hz, 1 min.)
Typical current consumption
Max. current consumption
≤ 2 A (For operation in a joining station, via the DIN rail connector)
Maximum switching voltage
Limiting continuous current
Connection method
COMBICON plug-in screw terminal block
D-SUB 9 plug
SC duplex
Single conductor/terminal point, rigid
Single-wire/terminal point, flexible
Conductor cross-section, flexible [AWG]
Tightening torque
0.4 Nm
0.56 Nm ... 0.79 Nm
Transmission channels
2 (1/1), RxD, TxD, full duplex
Transmit capacity, minimum
-3.4 dBm (50/125 μm, multimode fiberglass)
-4.7 dBm (62.5/125 μm, multimode fiberglass)
-5.5 dBm (9/125 μm, singlemode fiberglass)
Transmission length incl. 3 dB system reserve
22 km (with F-G 62.5/125 0.8 dB/km at 1300 nm)
27 km (With F-G 50/125 0.7 dB/km at 1300 nm)
45 km (With F-E 9/125 0,4 dB/km at 1300 nm)
Transmission protocol
Transparent to protocol for RS-232 interface
Minimum receiver sensitivity
-25.5 dBm (50/125 μm, multimode fiberglass)
-25.5 dBm (62.5/125 μm, multimode fiberglass)
-26.5 dBm (9/125 μm, singlemode fiberglass)
Maximum receiver sensitivity
Transmission medium
Copper
Multi-mode fiberglass
Single-mode fiberglass
Serial transmission speed
Fiber types
50/125 µm
9/125 µm
Fiberglass
Vibration resistance in accordance with EN 60068-2-6/IEC 60068-2-6
Operation: 5g, 10...150 Hz, 2.5 h, in XYZ direction
Shock in accordance with EN 60068-2-27/IEC 60068-2-27
Operation: 15g, 11 ms period, half-sine shock pulse
Ambient temperature (operation)