EMC note
EMC: class A product, see manufacturer's declaration in the download area
Electrical isolation between input and output
Maximum power dissipation for nominal condition
Maximum temperature coefficient
Transmission error in the set measuring range
Transmission error in the full measuring range
Standards/regulations
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-6-4
IEC/EN 61010
Supply voltage range
19.2 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Sensor types (RTD) that can be used
Pt 100 (IEC 60751/EN 60751)
Temperature measuring range
Temperature measuring range: Pt 100
-50 °C ... 200 °C (configurable)
Max. permissible overall conductor resistance
Configurable/programmable
Voltage output signal
0 V ... 10 V
0 V ... 5 V
1 V ... 5 V
10 V ... 0 V
Max. voltage output signal
Current output signal
0 mA ... 20 mA
20 mA ... 0 mA
20 mA ... 4 mA
4 mA ... 20 mA
Max. current output signal
Load/output load voltage output
Load/output load current output
Ripple
< 20 mV<sub>PP</sub> (at 10 kΩ)
< 20 mV<sub>PP</sub> (at 500 Ω)
Conductor cross-section rigid
Conductor cross-section flexible
Conductor cross-section AWG