Your Language:
English (en)
en
English
lt
Lietuviškai
Debug
Administrator
Testing
did you mean:
Show more results in separate page
0 items
000
Your basket is empty
Total price for 0 items 000
All prices without tax
All prices with tax
Order
Proceed to basket details
EMD-FL-3V-230 Monitoring relay
N
0%
2885773

EMD-FL-3V-230 Monitoring relay

Manufactured by
Brand PHOENIX CONTACT
Monitoring relay for monitoring 3-phase voltages of 160…300 V AC, undervoltage, window, phase sequence, phase failure, asymmetry, wide range power supply unit, 2 changeover contacts
4046356100786
only
available
100+
21
pcs.
()
Supply from Phoenix Contact’s warehouse
Product recommended retail price (RRP) is
000
25720 0 € pcs.
All prices without tax
All prices with tax
inquiry
only
available
100+
inquiry
21
pcs.
Properties
Description
Dimensions
Files
Codes
Nominal input voltage UN
3 N ~ 230/132 V
Product type
Voltage monitoring relay
Operating mode
100% operating factor
Mechanical service life
approx. 2x 10<sup>7</sup> cycles
Insulation
Basic insulation
Overvoltage category
III
Pollution degree
2
Service life electrical
2x 10<sup>5</sup> cycles at ohmic load, 1000 VA
Mains type
3-phase
Rated insulation voltage
300 V
Rated surge voltage
4 kV
Supply voltage range
24 V AC ... 240 V AC -15 % ... +10 %
24 V DC ... 240 V DC -20 % ... +25 %
Nominal power consumption
4.5 VA (1.5 W)
Input name
Measuring input
Measured value
AC sine (48 Hz ... 63 Hz)
Protection
≤ 20 A
Nominal input voltage U&lt;sub&gt;N&lt;/sub&gt;
3 N ~ 230/132 V
Maximum input voltage
345 V (3 N ~ 345/199 V)
Input resistance of voltage input
470 kΩ
Frequency range
48 Hz ... 400 Hz
Maximum temperature coefficient
< 0.1 %/K
Setting range for response delay
0.1 s ... 10 s
Min. setting range
-30 % ... 20 % (From U<sub>N</sub>)
Max. setting range
-20 % ... 30 % (From U<sub>N</sub>)
Min setting range of the voltage threshold value
161 V AC ... 276 V AC
Max. setting range of the voltage threshold value
184 V AC ... 299 V AC
Function
Asymmetry
Phase failure
Phase sequence
Undervoltage
Window
Basic accuracy
± 5 % (of scale end value)
Setting accuracy
≤ 5 % (of scale end value)
Repeat accuracy
≤ 2 %
Asymmetry
5 % ... 25% / OFF
Recovery time
500 ms
Contact switching type
2 floating changeover contacts
Maximum switching voltage
250 V AC
Interrupting rating (ohmic load) max.
1250 VA (5 A/250 V AC, module not aligned, ≥ 5 mm spacing)
750 VA (3 A/250 V AC, module aligned, ≤ 5 mm spacing)
Output fuse
5 A (fast-blow)
Connection method
Screw connection
Stripping length
8 mm
Conductor cross-section rigid
0.5 mm² ... 2.5 mm²
Conductor cross-section flexible
0.25 mm² ... 2.5 mm²
Conductor cross-section AWG
20 ... 14
Width
22.5 mm
Height
90 mm
Depth
113 mm
Color
green (RAL 6021)
Housing insulation material
Polyamide PA, self-extinguishing
Degree of protection (Housing)
IP40 (Housing)
Degree of protection (Connection terminal blocks)
IP20 (Connection terminal blocks)
Ambient temperature (operation)
-25 °C ... 40 °C (corresponds to UL 508)
-25 °C ... 55 °C
Ambient temperature (storage/transport)
-25 °C ... 70 °C
Length
0
m
Width
0
m
Height
0
m
Weight Net
0
kg
Weight
0
kg
Package
0
kg
Volume
0
No files found
ECLASS-13.0
27371801
ECLASS-15.0
27371801
ETIM 10.0
EC001438
UNSPSC 21.0
41113600
GTIN
4046356100786
Item accessories
No item accessories found
No related items found