Notes on operation
Do not connect adjacent channels to SELV/ PELV and voltages dangerous to the touch.
Do not use to separate SELV / PELV circuits from other circuits, because safe isolation is not guaranteed.
The PLC-ATP partition plate must be installed for voltages greater than 250 V (L1, L2, L3) between identical terminal blocks on adjacent modules.
The PLC-ATP separating plate should be installed for safe isolation between adjacent modules
The system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact.
Rated actuating voltage UC
Rated actuating current IC
Switching threshold "0" signal in reference to UN
Application
With integrated solid-state relay
Switching threshold "1" signal in reference to UN
Date of last data management
Maximum power dissipation for nominal condition
Rated actuating voltage U<sub>C</sub>
Rated actuating current I<sub>C</sub>
Switching threshold "0" signal in reference to U<sub>N</sub>
Switching threshold "1" signal in reference to U<sub>N</sub>
Operating voltage display
Protective circuit
Inverse diode
Reverse polarity protection; Polarity protection diode
Surge protection
Surge protection; Suppressor diode
Designation
Alarm output
DC voltage output
Output voltage range
3 V DC ... 33 V DC
8 V DC ... 33 V DC
Limiting continuous current
10 A (see derating curve)
100 mA
Voltage drop at max. limiting continuous current
Output circuit
2-conductor, floating
3-conductor, ground-referenced
Conductor cross-section rigid
Conductor cross-section flexible
0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross-section AWG
Flammability rating according to UL 94 (Housing)
Degree of protection (Installation location)
IP54 (Installation location)
Ambient temperature (operation)
Ambient temperature (storage/transport)