MTTF
156 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
404 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
999 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
Rated insulation voltage
60 V (In accordance with EN/IEC 60079-7)
Electrical isolation
300 V (Rated insulation voltage (to adjacent devices, basic insulation in accordance with EN/IEC 61010))
Test voltage for analog I/Os
1.5 kV AC (50 Hz, 1 min.)
Maximum power dissipation for nominal condition
Transient surge protection
Supply voltage range
19.2 V DC ... 30.5 V DC (DIN rail bus connector)
Max. current consumption
≤ 115 mA (At 24 V DC, at 25°C)
Max. voltage output signal
Current output signal
0 mA ... 20 mA
4 mA ... 20 mA
Max. current output signal
Precision
≤ 0.02 % (at 25 °C)
typ. 0.5 % (Voltage output)
Temperature coefficient, typical
typ. 0.0025 %/K (at -40 °C ... +70 °C)
Protective circuit
Transient protection of outputs
Tightening torque
0.5 Nm ... 0.6 Nm
5 lb<sub>f</sub>-in. ... 7 lb<sub>f</sub>-in.
Conductor cross-section, rigid min.
Conductor cross-section, rigid max.
Conductor cross-section flexible min.
Conductor cross-section flexible max.
Conductor cross-section AWG min.
Conductor cross-section AWG max.
Status display
Green LED (bus communication, DAT)
LED periphery error, ERR (red)
LED supply voltage, PWR (green)
Flammability rating according to UL 94
Ambient temperature (operation)
-40 °C ... 70 °C (>55°C derating, see technical documentation)
-40 °F ... 158 °F (>131°F derating, see technical documentation)
Ambient temperature (storage/transport)
-40 °C ... 85 °C
-40 °F ... 185 °F
Permissible humidity (operation)
Permissible humidity (storage/transport)
Vibration (operation)
in accordance with IEC 60068-2-6: 5g, 10 Hz ... 150 Hz
Certificate
2022122310115625
CE-compliant
IBExU 15 ATEX B008 X
IECEx IBE 13.0019X
KTL 20-KA4BO-0148X
R-R-PCK-2901538
Identification
508 Listed
Class I, Div. 2, Groups A, B, C, D T4A
Class I, Zone 2, IIC T4
Ex ec IIC T4 Gc
ISA-S71.04-1985 G3 Harsh Group A
II 3 G Ex ec IIC T4 Gc
Note
Please follow the special installation instructions in the documentation!