EMC note
EMC: class A product, see manufacturer's declaration in the download area
Electrical isolation between input and output
Signal transmission behavior
Maximum temperature coefficient
Temperature coefficient, typical
Maximum transmission error
0.05 % (of final value in repeater power supply operation)
0.1 % (of final value in isolator operation)
Standards/regulations
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-6-4
GB/T 3836.1
GB/T 3836.3
GB/T 3836.4
IEC/EN 61010-1
Supply voltage range
9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Typical current consumption
110 mA (at 12 V DC and in repeater power supply operation)
25 mA (at 24 V DC and in isolator operation)
50 mA (at 24 V DC and in repeater power supply operation)
55 mA (at 12 V DC and in isolator operation)
Power consumption
≤ 1400 mW (at I<sub>OUT</sub> = 20 mA, 9.6 V DC, 600 Ω load)
Current input signal
0 mA ... 20 mA (isolator operation)
4 mA ... 20 mA (repeater power supply and isolator operation)
Input resistance current input
~ 68 Ω (+0.7 V for test diode)
Transmitter supply voltage
Current output signal
0 mA ... 20 mA (isolator operation)
4 mA ... 20 mA (repeater power supply and isolator operation)
Max. current output signal
Load/output load current output
Ripple
< 20 mV<sub>PP</sub> (600 Ω)
Conductor cross-section rigid
0.14 mm² ... 2.5 mm² (without ferrule)
0.2 mm² ... 2.5 mm² (with ferrule)
Conductor cross-section flexible
Conductor cross-section AWG
Status display
Green LED (supply voltage)
Fire protection for rail vehicles (DIN EN 45545-2) R22
Fire protection for rail vehicles (DIN EN 45545-2) R23