CCCex note
Use in potentially explosive areas is not permitted in China.
MTTF
101 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
1400 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
599 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
MTBF
140 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
479 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
Signal delay
± 1.3 µs (Store and Forward mode, 10/100 Mbps, depending on the frame size)
Basic functions
Store-and-forward media converter
Electrical isolation
according to IEEE 802.3
VCC // FE // Ethernet
Maximum power dissipation for nominal condition
Test voltage data interface/power supply
0.5 kV<sub>rms</sub> (50 Hz, 1 min.)
Supply voltage range
18 V DC ... 30 V DC (as an alternative or redundant, via backplane bus contact and system current supply)
18 V DC ... 30 V DC (Screw connection)
Typical current consumption
Protective circuit
Reverse polarity protection
Connection method
Plug-in screw terminal block (COMBICON), redundancy possible
RJ45 jack, shielded
SC duplex
Single conductor/terminal point, rigid
Single-wire/terminal point, flexible
Conductor cross-section, flexible [AWG]
Signal
± 1 kV (Data line, asymmetrical)
± 2 kV (Test Level 3)
Ethernet
Transmit capacity, minimum
≥ -20 dBm ((62,5/125 µm) dynamic in link mode (average))
≥ -23.5 dBm ((50/125 µm) dynamic in link mode (average))
Transmit capacity, maximum
≤ -14 dBm ((50/125 µm) dynamic in link mode (average))
≤ -14 dBm ((62,5/125 µm) dynamic in link mode (average))
Transmission length incl. 3 dB system reserve
10 km (F-G 62.5/125 0.7 dB/km F 1000)
2.8 km (F-G 50/125 1.6 dB/km F 800)
3 km (F-G 62.5/125 2.6 dB/km F 600)
6.4 km (F-G 50/125 0.7 dB/km F 1000)
Minimum receiver sensitivity
-31 dBm (dynamic in link mode (average))
Maximum receiver sensitivity
-14 dBm (dynamic in link mode (average))
Transmission medium
Copper
GI-HCS fiber
Multi-mode fiberglass
Transmission length
100 m (shielded twisted pair)
Signal LEDs
Activity, link status, 10/100 Mbps
Fiber types
50/125 µm
62.5/125 µm
Fiberglass
Free fall in accordance with IEC 60068-2-32
Vibration resistance in accordance with EN 60068-2-6/IEC 60068-2-6
Operation: 5g, 10...150 Hz, 2.5 h, in XYZ direction
Shock in accordance with EN 60068-2-27/IEC 60068-2-27
Operation: 25g, 11 ms period, half-sine shock pulse
Ambient temperature (operation)
Ambient temperature (storage/transport)
Altitude
≤ 2000 m (in acc. with UL)
≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Permissible humidity (operation)
5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)
5 % ... 95 % (non-condensing)