MTTF
13381 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
18372 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
3348 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
MTBF
12264 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
38062 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
Insulation voltage input/output
Test voltage data interface/data interface
Supply voltage range
passive module, no supply voltage required
Serial transmission speed
Connection method
M12 connector, D-coded (female)
Transmission length
≤ 100 m (Total length across both ports (dependent on data rate and cable used))
Protocols supported
Transparent protocol for IPv4 and IPv6
Shielding
capacitive isolation between both shield connections
no connection to protective earth ground (PE)
Vibration resistance in accordance with EN 60068-2-6/IEC 60068-2-6
Operation: 5g, 10...150 Hz, 2.5 h, in XYZ direction
Vibration resistance according to IEC 61373, EN 61373
Operation: Category 1, Class B
Shock in accordance with EN 60068-2-27/IEC 60068-2-27
Operation: 15g, 11 ms period, half-sine shock pulse
Storage/transport: 30g, 18 ms period, half-sine shock pulse
Ambient temperature (operation)
-40 °C ... 75 °C (85°C for 10 min.; thereafter function can no longer be guaranteed - check device)
Ambient temperature (storage/transport)
Altitude
≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Permissible humidity (operation)
Permissible humidity (storage/transport)
Identification
ISA-S71.04-1985 G3 Harsh Group A
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Standards/regulations
EN 50121 and EN 50155 (for railway applications)
EN 61000-4-4
EN 61000-6-4
IEC 60571
IEC 62368
Suitable in accordance with SELV EN 50153
Radio interference voltage in acc. with EN 55011
Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011
Class B, area of application: Industry and residential