Your Language:
English (en)
en
English
lt
Lietuviškai
Debug
Administrator
Testing
did you mean:
Show more results in separate page
0 items
000
Your basket is empty
Total price for 0 items 000
All prices without tax
All prices with tax
Order
Proceed to basket details
EMD-BL-V-230-PT Monitoring relay
N
0%
2903524

EMD-BL-V-230-PT Monitoring relay

Manufactured by
Brand PHOENIX CONTACT
Monitoring relay for monitoring 1-phase voltages of 24 V AC/DC or 230 V AC, undervoltage or window, 1 changeover contact, with Push-in connection
4046356747288
No suppliers found
Product recommended retail price (RRP) is
000
12180 0 € pcs.
All prices without tax
All prices with tax
inquiry
only
available
100+
inquiry
0
pcs.
Properties
Description
Dimensions
Files
Codes
Product type
Voltage monitoring relay
Operating mode
100% operating factor
Mechanical service life
15x 10<sup>6</sup> cycles
Insulation
Basic insulation
Overvoltage category
III
Pollution degree
2
Service life electrical
1x 10<sup>5</sup> cycles
Mains type
1-phase
Rated insulation voltage
250 V (Output circuit)
300 V (Supply circuit)
Rated surge voltage
4 kV
Supply voltage
-25 % ... +20 % (= measuring voltage)
Supply voltage range
-25 % ... +20 % (= measuring voltage)
Type of supply voltage
AC/DC
Nominal power consumption
0.6 W (at 24 V DC)
1.3 VA (At 24 V AC (0.8 W))
10 VA (At 230 V AC (0.6 W))
Input name
Measuring input
Measured value
DC, AC sine (48 Hz ... 63 Hz)
Input voltage range
0 V AC ... 230 V AC (Connection terminal blocks: U3 and GND)
0 V AC ... 24 V AC (Connection terminal blocks: U2 and GND)
0 V DC ... 24 V DC (Connection terminal blocks: U1 and GND)
Frequency range
48 Hz ... 63 Hz
Maximum temperature coefficient
≤ 0.05 %
Setting range for response delay
0.1 s ... 10 s
Min. setting range
75 % ... 115 % (From U<sub>N</sub>)
Max. setting range
80 % ... 120 % (From U<sub>N</sub>)
Function
Undervoltage
Window
Basic accuracy
≤ 5 % (of scale end value)
Setting accuracy
± 5 % (of scale end value)
Repeat accuracy
≤ 2 %
Recovery time
> 500 ms
Contact switching type
1 floating changeover contact
Maximum switching voltage
250 V AC (in acc. with IEC 60664-1)
Interrupting rating (ohmic load) max.
1250 VA (5 A / 250 V AC)
Output fuse
5 A (fast-blow)
Connection method
Push-in connection
Stripping length
8 mm
Conductor cross-section rigid
0.14 mm² ... 2.5 mm²
Conductor cross-section flexible
0.14 mm² ... 2.5 mm²
Conductor cross-section AWG
26 ... 14
Status display
LED (yellow)
Operating voltage display
Green LED
Error indication
Red LED
Width
17.5 mm
Height
89.5 mm
Depth
65.5 mm
Color
gray (RAL 7042)
Housing insulation material
Polyamide PA 6.6, self-extinguishing
Degree of protection (Housing)
IP40 (Housing)
Degree of protection (Connection terminal blocks)
IP20 (Connection terminal blocks)
Ambient temperature (operation)
-25 °C ... 55 °C
Ambient temperature (storage/transport)
-25 °C ... 70 °C
Climatic class
3K3 (in acc. with EN 60721)
Permissible humidity (operation)
15 % ... 85 %
Length
0
m
Width
0
m
Height
0
m
Weight Net
0
kg
Weight
0
kg
Package
0
kg
Volume
0
No files found
ECLASS-13.0
27371801
ECLASS-15.0
27371801
ETIM 10.0
EC001438
UNSPSC 21.0
41113600
GTIN
4046356747288
Item accessories
No item accessories found
No related items found