Notes on operation
Do not use to separate SELV / PELV circuits from other circuits, because safe isolation is not guaranteed.
The outputs are not suitable for switching different outer conductors.
Typical input current at UN
Input power dissipation for UN
Mechanical service life
approx. 10<sup>7</sup> cycles
Date of last data management
Maximum power dissipation for nominal condition
Test voltage (Winding/contact)
2.5 kV<sub>rms</sub> (50 Hz, 1 min., winding/contact)
Test voltage (Changeover contact/changeover contact)
2.5 kV<sub>rms</sub> (50 Hz, 1 min., changeover contact/changeover contact)
Nominal input voltage U<sub>N</sub>
Input voltage range
20.4 V AC ... 26.4 V AC (20 °C)
Typical input current at U<sub>N</sub>
Input power dissipation for U<sub>N</sub>
Typical response time
5 ms ... 25 ms (depending on phase relation)
Typical release time range
5 ms ... 20 ms (depending on phase relation)
Maximum switching voltage
Minimum switching voltage
Limiting continuous current
Maximum inrush current
50 A (20 ms, N/O contacts)
Interrupting rating (ohmic load) max.
108 W (at 60 V DC)
124 W (at 48 V DC)
384 W (at 24 V DC)
4000 VA (at 440 V AC)
4000 VA (for 250 V AC)
52 W (at 110 V DC)
70 W (at 220 V DC)
Motor load according to UL 508
1/2 HP, 240 V AC (single-phase AC motor)
1/2 HP, 240 V AC (three-phase induction motor)
1/3 HP, 120 V AC (single-phase AC motor)
Degree of protection (Installation location)
≥ IP54 (Installation location)
Ambient temperature (operation)
Ambient temperature (storage/transport)
Identification
EN 60068-2-60
ISA-S71.04. G3 Harsh Group