Your Language:
English (en)
en
English
lt
Lietuviškai
Debug
Administrator
Testing
did you mean:
Show more results in separate page
0 items
000
Your basket is empty
Total price for 0 items 000
All prices without tax
All prices with tax
Order
Proceed to basket details
UNO-PS/2AC/24DC/90W/C2LPS Power supply
N
0%
2904371

UNO-PS/2AC/24DC/90W/C2LPS Power supply

Manufactured by
Brand PHOENIX CONTACT
Primary-switched power supply unit UNO POWER, Screw connection, DIN rail mounting, input: 2-phase, output: 24 V DC / 3.75 A
4046356933483
No suppliers found
Product recommended retail price (RRP) is
000
13300 0 € pcs.
All prices without tax
All prices with tax
inquiry
only
available
100+
inquiry
0
pcs.
Properties
Description
Dimensions
Files
Codes
Inrush current integral (I2t)
< 0.5 A<sup>2</sup>s (typ.)
Nominal input voltage range
2x 400 V AC ... 500 V AC
Frequency range (fN)
50 Hz ... 60 Hz ±10 %
Input voltage range
2x 264 V AC ... 575 V AC
Extended input voltage range in operation
2x 264 V AC ... 320 V AC (Derating 10 %)
Nominal output current (IN)
3.38 A (Derating 10 %)
3.75 A
Derating
2x 264 V AC ... 320 V AC (Derating 10 %)
55 °C ... 70 °C (2.5 %/K)
Input voltage range AC
264 V AC ... 575 V AC (<320 V AC derating 2.5%/10 V)
Voltage type of supply voltage
AC
Inrush current
< 30 A (typ.)
Inrush current integral (I&lt;sup&gt;2&lt;/sup&gt;t)
< 0.5 A<sup>2</sup>s (typ.)
Frequency range (f&lt;sub&gt;N&lt;/sub&gt;)
50 Hz ... 60 Hz ±10 %
Mains buffering time
> 100 ms (500 V AC)
> 65 ms (400 V AC)
Current consumption
typ. 0.48 A (500 V AC)
typ. 0.55 A (400 V AC)
Nominal power consumption
211.3 VA
Protective circuit
Transient surge protection; Varistor
Power factor (cos phi)
0.48
Input fuse
2 A (slow-blow, internal)
Recommended breaker for input protection
6 A ... 16 A (Characteristics B, C, D, K)
Efficiency
typ. 89 % (400 V AC)
typ. 89 % (480 V AC)
Output characteristic
HICCUP
Nominal output voltage
24 V DC
Nominal output current (I&lt;sub&gt;N&lt;/sub&gt;)
3.38 A (Derating 10 %)
3.75 A
Feedback voltage resistance
< 35 V DC
Protection against overvoltage at the output (OVP)
≤ 35 V DC
Control deviation
< 0.1 % (change in input voltage ±10 %)
< 1 % (change in load, static 10 % ... 90 %)
< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
Residual ripple
< 50 mV<sub>PP</sub> (with nominal values)
Short-circuit-proof
yes
Output power
90 W
Maximum no-load power dissipation
< 0.7 W
Power loss nominal load max.
< 12 W
Rise time
< 0.5 s (U<sub>OUT</sub> (10 % ... 90 %))
Response time
< 2 ms
Connection in parallel
no
Connection in series
no
Connection method
Screw connection
Conductor cross-section, rigid min.
0.2 mm²
Conductor cross-section, rigid max.
2.5 mm²
Conductor cross-section flexible min.
0.2 mm²
Conductor cross-section flexible max.
2.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.
0.2 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.
2.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.
0.2 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.
2.5 mm²
Conductor cross-section AWG min.
24
Conductor cross-section AWG max.
14
Stripping length
8 mm
Screw thread
M3
Tightening torque, min
0.5 Nm
Tightening torque max
0.6 Nm
Length
0
m
Width
0
m
Height
0
m
Weight Net
0
kg
Weight
0
kg
Package
0
kg
Volume
0
No files found
ECLASS-13.0
27040701
ECLASS-15.0
27040701
ETIM 10.0
EC002540
UNSPSC 21.0
39121000
GTIN
4046356933483
Item accessories
0%
CBMC E4 24DC/1-4A NO Electronic circuit breaker
N
2906031 CBMC E4 24DC/1-4A NO Electronic circuit breaker
14320 0 €
only
available
100+
inquiry
1105
pcs.
0%
CBMC E4 24DC/1-10A NO Electronic circuit breaker
N
2906032 CBMC E4 24DC/1-10A NO Electronic circuit breaker
14320 0 €
only
available
100+
inquiry
1182
pcs.
0%
PLT-SEC-T3-24-FM-UT Type 3 surge protection device
N
2907916 PLT-SEC-T3-24-FM-UT Type 3 surge protection device
12930 0 €
only
available
100+
inquiry
70
pcs.
No related items found